Regulation 48. Selection of Tubes for Test

Official text — not yet verifiedGazette 1 Oct 2026 · printed pp. 528–530TableFormula / symbols

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

48.Selection of Tubes for Test.─(1) (a) (i)Test specimens required for the flattening, expanding or flaring test specified herein below shall be taken from the ends of finished tubes prior to upsetting swaging, expanding or any other forming operations or being cut to length.

(ii)They shall be smooth on the ends and free from burrs and flaws.

(b)(i) If desirable and practicable tensile test may be carried out on full section of the tubes up to the capacity of the testing machine.

(ii)For large size tubes, the tensile test specimen shall consist of strip cut longitudinally from the tube and which is not straightened within the gauge length and further heat treated.

(c)If any test specimen shows flaws or defective machining it shall be discarded and another specimen be taken into consideration.

(d)All specimens shall be tested at room temperature.

(2)(a)The test specified herein below shall be made on minimum two tubes for first hundred tubes and one per hundred or part thereof for tubes over 100 numbers from each lot.

(b)Lot applies to all tube of same size and wall thickness of same heat and heat treatment.

(3)(a)The test specimen shall comply with the requirements as specified in table 2/19.

(b)The hardness test may be carried out on the wall cross section or on a flat on the outside surface of the tube sample.

Table 2/19: Mechanical Property Requirements

SerialGradeYield strength MPa (kg/mm2) MinTensile Strength MPa (kg/mm2) Min% ElongationHardness
No.on GL= 50 mmHRB HB
min
max max
*
(1)(2)(3)(4)(5)(6)
1.SA 179180 (18.3)325 (33.1)3572130
2.SA 210 Gr A1255 (26.1)415 (42.2)3079143
3.SA 210 Gr C275 (28.2)485 (49.3)3089179
4.SA 209 Gr T1205 (21.1)380 (38.7)3080146
5.SA 213 Gr T2205 (21.1)415 (42.2)3085163
6.SA 213 Gr T5205 (21.1)415 (42.2)3085163
7.SA 213 Gr T9205 (21.1)415 (42.2)3089179
8.SA 213 Gr T11205 (21.1)415 (42.2)3085163
9.SA 213 Gr T12220 (22.5)415 (42.2)3085163
10.SA 213 Gr T22205 (21.1)415 (42.2)3085163
11.SA 213 Gr T91415 (42.2)585 (59.6)2025 HRC250
12.12X1Mφ12X1Mφ274 (28.0)274 (28.0)441 (45.0)212185163163
637 (65.0)
13.X20CrMoV121490 (50.0)690 (70.4)1725 HRC250
840 (85.7)
14.SA 213 TP 304205 (21.1)515 (52.5)3590192
15.SA 213 TP304H205 (21.1)515 (52.5)3590192
16.SA 213 TP304L170 (17.3)485 (49.5)3590192
17.SA 213 TP310S205 (21.1)515 (52.5)3590192
18.SA 213 TP316205 (21.1)515 (52.5)3590192
19.SA 213 TP316H205 (21.1)515 (52.5)3590192
20.SA 213 TP316L170 (17.3)485 (49.5)3590192
21.SA 213 TP321205 (21.1)515 (52.5)3590192
22.SA 213 TP321H205 (21.1)515 (52.5)3590192
23.SA 213 TP347205 (21.1)515 (52.5)3590192
24.SA 213 TP347H205 (21.1)515 (52.5)3590192
25.SB 167 N06617240 (24.5)655 (66.8)35--

Table structure read from the Gazette PDF, pages 528, 529. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Serial        Grade              Yield strength   Tensile Strength   % Elongation                 Hardness
 No.           (2)               MPa (kg/mm2)     MPa (kg/mm2)      on GL= 50 mm
                                                                                             HRB            HB
 (1)                                   Min               Min               min
                                                                            *            max                max
                                        (3)               (4)              (5)
                                                                                                  (6)

1.            SA 179                  180 (18.3)  325 (33.1)         35                      72        130

2.            SA 210 Gr A1            255 (26.1)  415 (42.2)         30                      79        143

3.            SA 210 Gr C             275 (28.2)  485 (49.3)         30                      89        179

4.            SA 209 Gr T1            205 (21.1)  380 (38.7)         30                      80        146

5.            SA 213 Gr T2            205 (21.1)  415 (42.2)         30                      85        163

6.            SA 213 Gr T5            205 (21.1)  415 (42.2)         30                      85        163

7.            SA 213 Gr T9            205 (21.1)  415 (42.2)         30                      89        179


8.   SA 213 Gr T11  205 (21.1)               415 (42.2)  30                            85      163
                    220 (22.5)               415 (42.2)
9.   SA 213 Gr T12  205 (21.1)               415 (42.2)  30                            85      163
                    415 (42.2)               585 (59.6)
10. SA 213 Gr T22   274 (28.0)               441 (45.0)  30                            85      163
                                             637 (65.0)
11. SA 213 Gr T91   490 (50.0)               690 (70.4)  20                            25 HRC  250
                                             840 (85.7)
12.  12X1Mφ         205 (21.1)               515 (52.5)  21                            85      163
                    205 (21.1)               515 (52.5)
13. X20CrMoV121     170 (17.3)               485 (49.5)  17                            25 HRC  250
                    205 (21.1)               515 (52.5)
14. SA 213 TP 304   205 (21.1)               515 (52.5)  35                            90      192
15. SA 213 TP304H   205 (21.1)               515 (52.5)
16. SA 213 TP304L   170 (17.3)               485 (49.5)  35                            90      192
17. SA 213 TP310S   205 (21.1)               515 (52.5)
18. SA 213 TP316    205 (21.1)               515 (52.5)  35                            90      192
19. SA 213 TP316H   205 (21.1)               515 (52.5)
20. SA 213 TP316L   205 (21.1)               515 (52.5)  35                            90      192
21. SA 213 TP321    240 (24.5)               655 (66.8)
22. SA 213 TP321H                                        35                            90      192
23. SA 213 TP347
24. SA 213 TP347H                                        35                            90      192
25. SB 167 N06617
                                                         35                            90      192

                                                         35                            90      192

                                                         35                            90      192

                                                         35                            90      192

                                                         35                            90      192
Original extracted text of the table above, continued (diagnostic)
35                            -       -

*The tensile test specimen shall be as per the relevant material specifications.

Note: For longitudinal strip tests of Carbon steel a deduction in percentage elongation 1.5% shall be made for each 0.8 mm decrease in wall thickness under 8 mm from the minimum elongation value requirement.

(4)A section of the tube not less than 63 mm in length shall be flattened cold between two parallel flat surfaces to a distance between the plates (H) as calculated by the formula given below, without showing any sign of a crack or flaw:

H = (1 + e) t / e + t/D

Where, t = specified thickness of tube (mm)
D = specified outside diameter of the tube (mm)
e = a constant, as given below
e = 0.07 for Carbon steel with maximum specified carbon above 0.18% e = 0.09 for Carbon steel with maximum specified carbon 0.18% or less. e = 0.08 for alloy steel
e = 0.09 for Austenitic steel

Note: No flattening test required for grade N06617.

(5)A section of the tube approximately 100 mm in length shall stand being flared with a tool having a 60° included angle until the tube at the mouth of the flare has been expanded to the percentages given below, without cracking:

Serial No.Ratio of inside diameter to outside diameterMinimum expansion of inside diameter %
(1)(2)(3)
1.0.921
2.0.822
3.0.725
4.0.630
5.0.539
6.0.451
7.0.368

Table structure read from the Gazette PDF, page 530. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Serial No.                                  Table 2/20         Minimum expansion of inside diameter %
       (1)   Ratio of inside diameter to outside diameter                             (3)
         1.                                                                           21
         2.                          (2)                                              22
         3.                          0.9                                              25
         4.                          0.8                                              30
         5.                          0.7                                              39
         6.                          0.6                                              51
         7.                          0.5                                              68

0.4

0.3

Note: No expanding or flaring test required for grade N06617.

(6)(a)(i) If any one or more tests specified in these regulations fail, two further tests of the same kind may be made on two other tubes of the same batch.

(ii)If any of these tests fails, the batch of the tubes represented may be given a further heat treatment and entire set of test shall be repeated.

(b)If the repeat tests are satisfactory the tubes shall be accepted. If any failure in the tests should occur, the entire batch of the tubes shall be rejected.

(7)(a)Each tube shall be tested by the manufacturer and shall withstand a hydraulic pressure of one and half times of the design pressure subject to a minimum of 1 kg/mm2, but not greater than pressure calculated by the following formula:

P= 2St/D

Where, P = test pressure
D = specified outside diameter of the tube
t = specified wall thickness of the tube

S = stress which shall be taken as 40% of the minimum tensile strength at room temperature for carbon and alloy steel and 80% of the minimum yield strength at room temperature for austenitic stainless steel.

(b)Despite anything contained in the clause(a), the hydraulic test at the maker’s works may be dispensed with, provided that the tubes are subject to non-destructive testing by an appropriate method like Ultrasonic or Eddy Current or Stray Flux testing.

Parts of this extracted text look garbled; read the Gazette page before using any value.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 48 sets how seamless tubes are sampled and tested: tensile and hardness, flattening, flaring, retests and the hydraulic test.

Key points

  • (1) Flattening, expanding or flaring specimens are taken from the ends of finished tubes before forming or cutting to length. Tensile tests may use the full tube section, or for large tubes a longitudinal strip not straightened within the gauge length. All specimens are tested at room temperature.
  • (2) Test at least two tubes for the first hundred, and one per hundred or part thereof beyond 100, from each lot. A lot is tubes of the same size, wall thickness, heat and heat treatment.
  • (3) Mechanical properties must meet Table 2/19 (yield, tensile, % elongation on a 50 mm gauge length, hardness). For carbon steel longitudinal strip tests, deduct 1.5% elongation for each 0.8 mm decrease in wall thickness under 8 mm.
  • (4) Flattening. A section at least 63 mm long is flattened cold to the distance H = (1 + e) t / e + t/D without cracks. The Gazette prints this formula on one line; it is the usual flattening-test fraction, read as H = (1 + e)t divided by (e + t/D). Check the Gazette page before using it. The constant e depends on the steel: 0.07 or 0.09 for carbon steel depending on whether maximum carbon is above 0.18%, 0.08 for alloy steel and 0.09 for austenitic steel.
  • (5) Flaring. A section about 100 mm long is flared with a 60° tool to the minimum inside-diameter expansion in Table 2/20, which depends on the ratio of inside to outside diameter.
  • (7)(a) Hydraulic test. Each tube withstands one and half times the design pressure, minimum 1 kg/mm2, but not above P = 2St/D. S is 40% of minimum room-temperature tensile strength for carbon and alloy steel, and 80% of minimum room-temperature yield strength for austenitic stainless steel.

Watch out

  • (6) If a test fails, two more tests are made on two other tubes from the batch. If either fails, the batch may be re-heat treated and all tests repeated. If any failure then occurs, the entire batch is rejected.
  • (7)(b) The hydraulic test at the maker's works may be dispensed with if tubes get suitable NDT, such as Ultrasonic, Eddy Current or Stray Flux testing.
  • Grade N06617 needs no flattening, expanding or flaring test.
  • Tables 2/19 and 2/20 are misaligned in the extracted text. Check the Gazette page for the exact values.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
631Tubes100%Chapter XV (DPIIT scan), image 3
14Selection of test pieces83%Chapter II (DPIIT scan), image 1
82Selection of test pieces83%Chapter II (DPIIT scan), image 16

Amendment history of the candidate IBR 1950 regulations: Reg. 14 (1 amendment) · Reg. 82 (1 amendment)

IBR 1950 regulation 14 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 14 page for its amendments.

Reg. 14
MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Selection of test pieces

All test pieces shall be selected by the Inspecting Officer and tested in his presence, and he shall satisfy himself that the conditions herein described are fulfilled.

IBR 1950 regulation 82 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 82 page for its amendments.

Reg. 82
MATERIALS OF CONSTRUCTION

FORGED OR ROLLED PRESSURE PARTS OTHER THAN SEAMLESS DRUMS OF CARBON STEEL

Selection of test pieces

(a) For testing, either the parts themselves shall be used or additional material of sufficient size for test pieces shall be available. In the case of headers for example, surplus lengths for test rings may be used. In the case of flanges swaged in dies, the punching left may be used as test pieces in which case the identity of the material of the punching with that of the flange shall be evidenced in an adequate manner. The test may be performed also on the semi-finished material for example a bar or a billet, provided it is given approximately the same reduction and heat-treatment as the finished forgings. For headers with closed ends, the test rings shall be cut off before dishing or reducing and shall be subjected to the same heat treatment as the headers themselves. In the case of headers which are closed by special covers, the test ring shall be cut off after heat-treatment. Similar procedures shall be followed for test pieces of other forgings.

(b) For testing, piece of one and the same cast of the same heat treatment batch as well as of similar dimensions may be gathered into one group. At least one test piece shall be made from each group.

(c) A proportional test piece with Lo = 5 do shall be used as a test specimen.

(d) Tangential test piece shall be used for headers where practicable. For headers with outside diameter less than 200 mm longitudinal test pieces may be allowed.

(e) Hydraulic Test.- A hydraulic test shall be carried out at the Maker’s works in accordance with the requirements of  regulation 268, if required by the Inspecting Authority.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
528–530
PDF page index
528–530 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 00d61dd0ba4fa8e6
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 48, Regulation 48, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.528–530. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.