Indian Boiler Regulations, 2026 · Chapter 2 · Materials of Construction
Regulation 48. Selection of Tubes for Test
Not yet checked against the official Gazette; verify before relying on it.
48.Selection of Tubes for Test.─(1) (a) (i)Test specimens required for the flattening, expanding or flaring test specified herein below shall be taken from the ends of finished tubes prior to upsetting swaging, expanding or any other forming operations or being cut to length.
(ii)They shall be smooth on the ends and free from burrs and flaws.
(b)(i) If desirable and practicable tensile test may be carried out on full section of the tubes up to the capacity of the testing machine.
(ii)For large size tubes, the tensile test specimen shall consist of strip cut longitudinally from the tube and which is not straightened within the gauge length and further heat treated.
(c)If any test specimen shows flaws or defective machining it shall be discarded and another specimen be taken into consideration.
(d)All specimens shall be tested at room temperature.
(2)(a)The test specified herein below shall be made on minimum two tubes for first hundred tubes and one per hundred or part thereof for tubes over 100 numbers from each lot.
(b)Lot applies to all tube of same size and wall thickness of same heat and heat treatment.
(3)(a)The test specimen shall comply with the requirements as specified in table 2/19.
(b)The hardness test may be carried out on the wall cross section or on a flat on the outside surface of the tube sample.
Table 2/19: Mechanical Property Requirements
| Serial | Grade | Yield strength MPa (kg/mm2) Min | Tensile Strength MPa (kg/mm2) Min | % Elongation | Hardness | |||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| No. | on GL= 50 mm | HRB HB | ||||||||||||||
| min | ||||||||||||||||
| max max | ||||||||||||||||
| * | ||||||||||||||||
| (1) | (2) | (3) | (4) | (5) | (6) | |||||||||||
| 1. | SA 179 | 180 (18.3) | 325 (33.1) | 35 | 72 | 130 | ||||||||||
| 2. | SA 210 Gr A1 | 255 (26.1) | 415 (42.2) | 30 | 79 | 143 | ||||||||||
| 3. | SA 210 Gr C | 275 (28.2) | 485 (49.3) | 30 | 89 | 179 | ||||||||||
| 4. | SA 209 Gr T1 | 205 (21.1) | 380 (38.7) | 30 | 80 | 146 | ||||||||||
| 5. | SA 213 Gr T2 | 205 (21.1) | 415 (42.2) | 30 | 85 | 163 | ||||||||||
| 6. | SA 213 Gr T5 | 205 (21.1) | 415 (42.2) | 30 | 85 | 163 | ||||||||||
| 7. | SA 213 Gr T9 | 205 (21.1) | 415 (42.2) | 30 | 89 | 179 | ||||||||||
| 8. | SA 213 Gr T11 | 205 (21.1) | 415 (42.2) | 30 | 85 | 163 | ||||||||||
| 9. | SA 213 Gr T12 | 220 (22.5) | 415 (42.2) | 30 | 85 | 163 | ||||||||||
| 10. | SA 213 Gr T22 | 205 (21.1) | 415 (42.2) | 30 | 85 | 163 | ||||||||||
| 11. | SA 213 Gr T91 | 415 (42.2) | 585 (59.6) | 20 | 25 HRC | 250 | ||||||||||
| 12. | 12X1Mφ | 12X1Mφ | 274 (28.0) | 274 (28.0) | 441 (45.0) | 21 | 21 | 85 | 163 | 163 | ||||||
| 637 (65.0) | ||||||||||||||||
| 13. | X20CrMoV121 | 490 (50.0) | 690 (70.4) | 17 | 25 HRC | 250 | ||||||||||
| 840 (85.7) | ||||||||||||||||
| 14. | SA 213 TP 304 | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 15. | SA 213 TP304H | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 16. | SA 213 TP304L | 170 (17.3) | 485 (49.5) | 35 | 90 | 192 | ||||||||||
| 17. | SA 213 TP310S | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 18. | SA 213 TP316 | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 19. | SA 213 TP316H | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 20. | SA 213 TP316L | 170 (17.3) | 485 (49.5) | 35 | 90 | 192 | ||||||||||
| 21. | SA 213 TP321 | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 22. | SA 213 TP321H | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 23. | SA 213 TP347 | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 24. | SA 213 TP347H | 205 (21.1) | 515 (52.5) | 35 | 90 | 192 | ||||||||||
| 25. | SB 167 N06617 | 240 (24.5) | 655 (66.8) | 35 | - | - | ||||||||||
Table structure read from the Gazette PDF, pages 528, 529. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Serial Grade Yield strength Tensile Strength % Elongation Hardness
No. (2) MPa (kg/mm2) MPa (kg/mm2) on GL= 50 mm
HRB HB
(1) Min Min min
* max max
(3) (4) (5)
(6)
1. SA 179 180 (18.3) 325 (33.1) 35 72 130
2. SA 210 Gr A1 255 (26.1) 415 (42.2) 30 79 143
3. SA 210 Gr C 275 (28.2) 485 (49.3) 30 89 179
4. SA 209 Gr T1 205 (21.1) 380 (38.7) 30 80 146
5. SA 213 Gr T2 205 (21.1) 415 (42.2) 30 85 163
6. SA 213 Gr T5 205 (21.1) 415 (42.2) 30 85 163
7. SA 213 Gr T9 205 (21.1) 415 (42.2) 30 89 179
8. SA 213 Gr T11 205 (21.1) 415 (42.2) 30 85 163
220 (22.5) 415 (42.2)
9. SA 213 Gr T12 205 (21.1) 415 (42.2) 30 85 163
415 (42.2) 585 (59.6)
10. SA 213 Gr T22 274 (28.0) 441 (45.0) 30 85 163
637 (65.0)
11. SA 213 Gr T91 490 (50.0) 690 (70.4) 20 25 HRC 250
840 (85.7)
12. 12X1Mφ 205 (21.1) 515 (52.5) 21 85 163
205 (21.1) 515 (52.5)
13. X20CrMoV121 170 (17.3) 485 (49.5) 17 25 HRC 250
205 (21.1) 515 (52.5)
14. SA 213 TP 304 205 (21.1) 515 (52.5) 35 90 192
15. SA 213 TP304H 205 (21.1) 515 (52.5)
16. SA 213 TP304L 170 (17.3) 485 (49.5) 35 90 192
17. SA 213 TP310S 205 (21.1) 515 (52.5)
18. SA 213 TP316 205 (21.1) 515 (52.5) 35 90 192
19. SA 213 TP316H 205 (21.1) 515 (52.5)
20. SA 213 TP316L 205 (21.1) 515 (52.5) 35 90 192
21. SA 213 TP321 240 (24.5) 655 (66.8)
22. SA 213 TP321H 35 90 192
23. SA 213 TP347
24. SA 213 TP347H 35 90 192
25. SB 167 N06617
35 90 192
35 90 192
35 90 192
35 90 192
35 90 192Original extracted text of the table above, continued (diagnostic)
35 - -
*The tensile test specimen shall be as per the relevant material specifications.
Note: For longitudinal strip tests of Carbon steel a deduction in percentage elongation 1.5% shall be made for each 0.8 mm decrease in wall thickness under 8 mm from the minimum elongation value requirement.
(4)A section of the tube not less than 63 mm in length shall be flattened cold between two parallel flat surfaces to a distance between the plates (H) as calculated by the formula given below, without showing any sign of a crack or flaw:
H = (1 + e) t / e + t/D
Where, t = specified thickness of tube (mm)
D = specified outside diameter of the tube (mm)
e = a constant, as given below
e = 0.07 for Carbon steel with maximum specified carbon above 0.18% e = 0.09 for Carbon steel with maximum specified carbon 0.18% or less. e = 0.08 for alloy steel
e = 0.09 for Austenitic steel
Note: No flattening test required for grade N06617.
(5)A section of the tube approximately 100 mm in length shall stand being flared with a tool having a 60° included angle until the tube at the mouth of the flare has been expanded to the percentages given below, without cracking:
| Serial No. | Ratio of inside diameter to outside diameter | Minimum expansion of inside diameter % | ||||
|---|---|---|---|---|---|---|
| (1) | (2) | (3) | ||||
| 1. | 0.9 | 21 | ||||
| 2. | 0.8 | 22 | ||||
| 3. | 0.7 | 25 | ||||
| 4. | 0.6 | 30 | ||||
| 5. | 0.5 | 39 | ||||
| 6. | 0.4 | 51 | ||||
| 7. | 0.3 | 68 |
Table structure read from the Gazette PDF, page 530. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Serial No. Table 2/20 Minimum expansion of inside diameter %
(1) Ratio of inside diameter to outside diameter (3)
1. 21
2. (2) 22
3. 0.9 25
4. 0.8 30
5. 0.7 39
6. 0.6 51
7. 0.5 680.4
0.3
Note: No expanding or flaring test required for grade N06617.
(6)(a)(i) If any one or more tests specified in these regulations fail, two further tests of the same kind may be made on two other tubes of the same batch.
(ii)If any of these tests fails, the batch of the tubes represented may be given a further heat treatment and entire set of test shall be repeated.
(b)If the repeat tests are satisfactory the tubes shall be accepted. If any failure in the tests should occur, the entire batch of the tubes shall be rejected.
(7)(a)Each tube shall be tested by the manufacturer and shall withstand a hydraulic pressure of one and half times of the design pressure subject to a minimum of 1 kg/mm2, but not greater than pressure calculated by the following formula:
P= 2St/D
Where, P = test pressure
D = specified outside diameter of the tube
t = specified wall thickness of the tube
S = stress which shall be taken as 40% of the minimum tensile strength at room temperature for carbon and alloy steel and 80% of the minimum yield strength at room temperature for austenitic stainless steel.
(b)Despite anything contained in the clause(a), the hydraulic test at the maker’s works may be dispensed with, provided that the tubes are subject to non-destructive testing by an appropriate method like Ultrasonic or Eddy Current or Stray Flux testing.
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 48 sets how seamless tubes are sampled and tested: tensile and hardness, flattening, flaring, retests and the hydraulic test.
Key points
- (1) Flattening, expanding or flaring specimens are taken from the ends of finished tubes before forming or cutting to length. Tensile tests may use the full tube section, or for large tubes a longitudinal strip not straightened within the gauge length. All specimens are tested at room temperature.
- (2) Test at least two tubes for the first hundred, and one per hundred or part thereof beyond 100, from each lot. A lot is tubes of the same size, wall thickness, heat and heat treatment.
- (3) Mechanical properties must meet Table 2/19 (yield, tensile, % elongation on a 50 mm gauge length, hardness). For carbon steel longitudinal strip tests, deduct 1.5% elongation for each 0.8 mm decrease in wall thickness under 8 mm.
- (4) Flattening. A section at least 63 mm long is flattened cold to the distance H = (1 + e) t / e + t/D without cracks. The Gazette prints this formula on one line; it is the usual flattening-test fraction, read as H = (1 + e)t divided by (e + t/D). Check the Gazette page before using it. The constant e depends on the steel: 0.07 or 0.09 for carbon steel depending on whether maximum carbon is above 0.18%, 0.08 for alloy steel and 0.09 for austenitic steel.
- (5) Flaring. A section about 100 mm long is flared with a 60° tool to the minimum inside-diameter expansion in Table 2/20, which depends on the ratio of inside to outside diameter.
- (7)(a) Hydraulic test. Each tube withstands one and half times the design pressure, minimum 1 kg/mm2, but not above P = 2St/D. S is 40% of minimum room-temperature tensile strength for carbon and alloy steel, and 80% of minimum room-temperature yield strength for austenitic stainless steel.
Watch out
- (6) If a test fails, two more tests are made on two other tubes from the batch. If either fails, the batch may be re-heat treated and all tests repeated. If any failure then occurs, the entire batch is rejected.
- (7)(b) The hydraulic test at the maker's works may be dispensed with if tubes get suitable NDT, such as Ultrasonic, Eddy Current or Stray Flux testing.
- Grade N06617 needs no flattening, expanding or flaring test.
- Tables 2/19 and 2/20 are misaligned in the extracted text. Check the Gazette page for the exact values.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Tube flattening test distance H (regulation 48(4)) · Tube hydraulic test pressure at the manufacturer (regulation 48(7))
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 631 | Tubes | 100% | Chapter XV (DPIIT scan), image 3 |
| 14 | Selection of test pieces | 83% | Chapter II (DPIIT scan), image 1 |
| 82 | Selection of test pieces | 83% | Chapter II (DPIIT scan), image 16 |
Amendment history of the candidate IBR 1950 regulations: Reg. 14 (1 amendment) · Reg. 82 (1 amendment)
IBR 1950 regulation 14 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 14 page for its amendments.
| Reg. 14 MATERIALS OF CONSTRUCTION STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL |
| All test pieces shall be selected by the Inspecting Officer and tested in his presence, and he shall satisfy himself that the conditions herein described are fulfilled. |
IBR 1950 regulation 82 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 82 page for its amendments.
| Reg. 82 MATERIALS OF CONSTRUCTION FORGED OR ROLLED PRESSURE PARTS OTHER THAN SEAMLESS DRUMS OF CARBON STEEL Selection of test pieces |
| (a) For testing, either the parts themselves shall be used or additional material of sufficient size for test pieces shall be available. In the case of headers for example, surplus lengths for test rings may be used. In the case of flanges swaged in dies, the punching left may be used as test pieces in which case the identity of the material of the punching with that of the flange shall be evidenced in an adequate manner. The test may be performed also on the semi-finished material for example a bar or a billet, provided it is given approximately the same reduction and heat-treatment as the finished forgings. For headers with closed ends, the test rings shall be cut off before dishing or reducing and shall be subjected to the same heat treatment as the headers themselves. In the case of headers which are closed by special covers, the test ring shall be cut off after heat-treatment. Similar procedures shall be followed for test pieces of other forgings. (b) For testing, piece of one and the same cast of the same heat treatment batch as well as of similar dimensions may be gathered into one group. At least one test piece shall be made from each group. (c) A proportional test piece with Lo = 5 do shall be used as a test specimen. (d) Tangential test piece shall be used for headers where practicable. For headers with outside diameter less than 200 mm longitudinal test pieces may be allowed. (e) Hydraulic Test.- A hydraulic test shall be carried out at the Maker’s works in accordance with the requirements of regulation 268, if required by the Inspecting Authority. |
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 48, Regulation 48, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.528–530. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.