Worked example · Reg. 48
Tube flattening test distance H (regulation 48(4))
What the regulation requires
Regulation 48(4): a section of the tube not less than 63 mm in length is flattened cold between two parallel flat surfaces to a distance between the plates (H) calculated by the formula below, without showing any sign of a crack or flaw. As printed:
H = (1 + e) t / e + t/D
The formula is printed on one line. Read literally, "(1 + e) t / e + t/D" would add t/D to (1 + e) t / e. This example reads it as the fraction H = (1 + e) t / (e + t/D), with (e + t/D) as the denominator. Check this reading against the Gazette page before relying on it.
Symbols and units
As printed:
- t = specified thickness of tube (mm)
- D = specified outside diameter of the tube (mm)
- e = a constant:
- e = 0.07 for Carbon steel with maximum specified carbon above 0.18%
- e = 0.09 for Carbon steel with maximum specified carbon 0.18% or less
- e = 0.08 for alloy steel
- e = 0.09 for Austenitic steel
H is a distance between the plates, in mm (t and D are in mm; e is a number).
Worked example
Example values (hypothetical, not from the regulation): carbon steel tube with maximum specified carbon 0.18% or less, so e = 0.09; t = 4 mm; D = 50 mm.
- t / D = 4 / 50 = 0.08
- Denominator: e + t/D = 0.09 + 0.08 = 0.17
- Numerator: (1 + e) × t = 1.09 × 4 = 4.36 mm
- H = 4.36 / 0.17 = 25.647… mm
- Result: H = 25.65 mm (rounded to 2 decimal places).
For comparison only, the literal one-line reading would give 1.09 × 4 / 0.09 + 0.08 = 48.52 mm (2 decimal places), which is close to the 50 mm outside diameter itself. That is one reason the fraction reading is used here, but the Gazette page decides.
Checks and limits
- Specimen length not less than 63 mm; flattened cold; no crack or flaw (48(4)).
- No flattening test is required for grade N06617 (note to 48(4)).
- Specimens are taken from the ends of finished tubes before forming or cutting to length, are smooth on the ends and free from burrs and flaws, and are tested at room temperature (48(1)).
- Number of tubes tested per lot and re-test rules are in 48(2) and 48(6); not covered here.
- The example does not decide which material category a tube belongs to; that follows the tube's specification.
Educational example only. Not a design calculation; verify against the official Gazette and applicable requirements.
Calculator
Runs in your browser. Results are for learning only; check every input, unit and condition against the official Gazette text of regulation 48.