Worked example · Reg. 48
Tube hydraulic test pressure at the manufacturer (regulation 48(7))
What the regulation requires
Regulation 48(7)(a): each tube is tested by the manufacturer and must withstand a hydraulic pressure of one and half times the design pressure, subject to a minimum of 1 kg/mm2, but not greater than the pressure calculated by:
P= 2St/D
Symbols and units
As printed:
- P = test pressure
- D = specified outside diameter of the tube
- t = specified wall thickness of the tube
- S = stress which shall be taken as 40% of the minimum tensile strength at room temperature for carbon and alloy steel and 80% of the minimum yield strength at room temperature for austenitic stainless steel.
48(7) does not print units for P, S, t or D. In this example t and D are in mm (as in 48(4)) and P and S are in kg/mm2, so that the printed minimum of 1 kg/mm2 can be applied directly. Table 2/19 in 48(3) prints minimum strengths as MPa (kg/mm2); the kg/mm2 figure is used here.
Worked example
Example values (hypothetical, except the strength taken from Table 2/19): tube of grade SA 210 Gr A1 (carbon steel), minimum tensile strength 42.2 kg/mm2 (Table 2/19, serial 2); t = 4 mm; D = 50 mm; design pressure 0.8 kg/mm2.
- S = 40% × 42.2 = 16.88 kg/mm2 (carbon steel rule)
- Upper limit: P = 2 × S × t / D = 2 × 16.88 × 4 / 50 = 135.04 / 50 = 2.7008 kg/mm2
- One and half times the design pressure: 1.5 × 0.8 = 1.2 kg/mm2
- Minimum: 1.2 kg/mm2 is not less than 1 kg/mm2, so the minimum does not govern.
- 1.2 kg/mm2 is not greater than 2.7008 kg/mm2, so the upper limit does not govern.
- Result: test pressure = 1.2 kg/mm2 (exact; upper limit shown to 4 decimal places).
If the design pressure were 0.5 kg/mm2 instead, 1.5 × 0.5 = 0.75 kg/mm2, which is below the minimum, so the test pressure would be 1 kg/mm2.
Checks and limits
- The 1 kg/mm2 minimum and the P = 2St/D upper limit can conflict for thin, large-diameter tubes (when 2St/D is below the required value). The regulation text does not say how to resolve that case; the calculator flags it rather than deciding.
- For austenitic stainless steel, S uses 80% of the minimum yield strength, not the tensile strength.
- 48(7)(b): despite clause (a), the hydraulic test at the maker's works may be dispensed with if the tubes are subject to non-destructive testing by an appropriate method like Ultrasonic or Eddy Current or Stray Flux testing.
- The example does not cover how the design pressure is determined or any test duration.
Educational example only. Not a design calculation; verify against the official Gazette and applicable requirements.
Calculator
Runs in your browser. Results are for learning only; check every input, unit and condition against the official Gazette text of regulation 48.