63.GENERAL GREY IRON CASTINGS (GRADE A).─ (1) The castings shall be cast from metal melted or refined in any metallurgical plant other than an iron ore smelting furnace, for the use of which furnace permission in writing must be received from the Inspecting Authority.

(2)The Composition of the iron as cast shall be left to the discretion of the manufacturer but the maximum percentage of phosphorus or sulphur or both may be specified by the Inspecting Authority, if it so desires.

(3)The castings shall be accurately moulded in accordance with the pattern or working drawings supplied by the Inspecting Authority with the addition of such letters, figures or marks as may be specified and the drawings shall include the tolerances specified in the regulation.

(4)(a)The castings shall be sound, clean out of twist and free from blow holes distortion and all surface and other defects.

(b)They shall be well dressed or fettled and shall be machinable by normal methods.

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 63 sets the basic requirements for general grey iron castings (Grade A): where the metal may be melted, its composition, moulding and the quality of the finished casting.

Key points

  • (1) The metal may be melted or refined in any metallurgical plant other than an iron ore smelting furnace. Using such a furnace needs written permission from the Inspecting Authority.
  • (2) The composition is left to the manufacturer, but the Inspecting Authority may specify the maximum phosphorus or sulphur percentage, or both.
  • (3) Castings are moulded to the pattern or working drawings supplied by the Inspecting Authority, with any letters, figures or marks it specifies. The drawings include the tolerances.
  • (4)(a) Castings must be sound, clean, out of twist and free from blow holes, distortion and surface or other defects.
  • (4)(b) They must be well dressed or fettled and machinable by normal methods.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
52General100%Chapter II (DPIIT scan), image 9
276General100%Chapter V (DPIIT scan), image 11
317General100%Chapter VI (DPIIT scan), image 7

Amendment history of the candidate IBR 1950 regulations: Reg. 52 (2 amendments)

IBR 1950 regulation 52 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 52 page for its amendments.

Reg. 52
MATERIALS OF CONSTRUCTION

SEAMLESS FERRITIC PIPES FOR HIGH TEMPERATURE SERVICE

General

(i) These regulations cover both hot finished and cold drawn seamless pipes of ferritic alloy steel grades.  These shall conform in all respects with the requirements herein specified.

(ii)  The seamless pipes conforming to other national/international standards which are known to be commonly used as being suitable for high temperature service can also be used with the designations of the national/international standards, provided such materials are not specifically prohibited by the regulations.

(iii)  While making pipes to other national/international standards the allowable stresses of the respective standard shall be strictly followed while designing the tubes.

(iv)   The design metal temperatures shall not exceed the following limits

Grade                                                              Temp. Degree C (Degree F)

P1, P2                                                                          537 (1000)

P5, P9, P11, P12, P22, P91, X20CrMoV121                    648 (1200)

IBR 1950 regulation 276 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 276 page for its amendments.


Reg. 276, Reg. 277


General

The thickness T specified in equation 74 of Regulation 278 is the thickness of the end plate after manufacture and is applicable over the whole area of the end plate up to the point where, for ends of partially spherical shape, the dishing radius joins the corner radius; from this point a gradual thinning is permissible up to maximum of 10 per cent of the thickness T at the point where the corner radius joins the straight portion of flanged end plate. A similar gradual thinning is permissible for end plates of semi-ellipsoidal shape. This permissible reduction in thickness applies also to the flange for the manhole opening. In no case, however, when the end plate is but welded to the drum shell, shall the thickness of the edge of the flange for connection to the shell be less than the thickness of an unpierced seamless shell of the same diameter and material, determined by equation 72.


Reg. 277

Dished End with Opening

a) Heads with openings:-
i) Holes cut in the heads (manholes or tube holes) should be round or elliptical.
ii) Small size openings complying with conditions of sub-regulation (c) do not require any additional thickness of head or reinforcement of opening.
iii)

Large size openings require an increase in thickness of the head, according to sub-regulation (b) or a reinforcement of the opening according to sub-regulation (d).

b) Shape factor K for heads with large unreinforced openings:- The shape factor K to be used in calculating the thickness of heads varies depending on the height of the head H and on the dimensions of the largest opening. The value of K is indicated in Fig. 23D, by means of curves, each of which corresponds to a value of the ratio.-
   d  ---------
Ö D T

where,

d = diameter of the largest opening in the head (in the case of an elliptical opening, the larger diameter of the ellipse);
D = outside diameter of the head; and
T = minimum thickness after dishing.

In addition, the following conditions shall be satisfied:

T < 0.1
D

d < 0.5
D

The same condition and the same curves apply for openings simply cut in the plate of the head as well as to those which are flanged inwards. In the latter case, the radius r’ of the flanging (see Fig. 23C) should not be smaller than 25 mm (1 inch). The thickness of the flanged portion may be smaller than the calculated thickness T.

Unreinforced openings and flanged-in openings in dished heads shall be arranged so that the distance from the edge of the head is not less than as shown in Fig. 23E.

In all cases the width of the band separating two adjacent openings should, in projection, be at least equal to the diameter of the smallest opening as shown in Fig. 23E.
c) Small openings which do not require any reinforcement:-

Figure 23D indicates that for a given ratio of H/d, the shape factor K of a plain head corresponds to a certain values of the ratio,

d       
(DT)1/2

Piercing of holes with a diameter smaller than or equal to that which corresponds to this value can thus be made without any reinforcement in a head, the thickness of which is equal to the minimum required for a plain head.

The position of those openings shall however comply with the conditions stated in sub-regulation (b).

d) Reinforcement of large openings:-Large holes may be cut without increasing the thickness of the head, provided they are sufficiently reinforced.

The reinforcement may consist either of a welded nozzle or one or two reinforcing welded plates, or of a combination of these two procedures.

To determine the strength of the construction, one shall proceed as follows (see Fig. 23F). Let the imaginary diameter d’ of the opening be given by the formula

d' = d - A
T

where,

d = actual diameter of the opening in the head (outside diameter of the nozzle);
T = minimum thickness of the head; and
A = effective cross-section of reinforcement.

This effective area A corresponds, within the Limits given below, with the actual cross-section of the reinforcing plates and with the cross-section of the nozzle decreased by the cross-section necessary to support the pressure, for those parts of the nozzle situated outside the internal surface of the head.

The shape factor K can then be read corresponding to the ratio
     
d         
(DT)1/2

The maximum limits for the are of reinforcement that should be taken into account are

(a) L1 = (2 RT)1/2. for the width of a reinforcing plate;
(b) L2 = (d Tt)1/2 for the length of a nozzle.

where,

R = internal radius of the spherical part of the head (or for elliptical heads the internal radius of curvature of the meridian at the centre of the opening)
Tt = actual thickness of the nozzle,
L1 and L2 = dimensions given in Fig. 23F.

The position of the outer edges of the reinforcement shall comply with the provisions of sub-regulation (b) and Fig. 23E.

In cases where the allowable stress of a part of the reinforcement is lower than that of the head, the corresponding area A should be multiplied by the ratio:

allowable stress of the reinforcement material -------------------------------------------------------------------------------------- allowable stress of the head material
IBR 1950 regulation 317 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 317 page for its amendments.

Reg. 317, Reg. 318, Reg. 319, Reg. 320
BLOW-DOWN COCK OR VALVE AND PIPES

General

The blow down cock or valve shall be of substantial construction. The waste pipe attached to the cock or valve shall not be bound fast in earth or brick work and shall discharge at a point where there is no danger of injury to any person. These pipes shall not be connected to a pipe common to another boiler. The continuous blow-downs may, however, be connected to a common header discharging freely to an adequately vented tank or sump. The headers shall be of sufficiently large cross section and the blow-off tank shall be provided with a vent pipe free from valves and of sufficient size to prevent accumulation of pressure. If, however, the tank is intended for collecting flash steam, a safety valve of adequate capacity shall be provided. The tank shall be so located that all parts will be accessible for inspection.


Reg. 318

Blow-down Mountings

a) Each boiler shall be fitted, with a suitable blow down valve or cock placed at, or as near as practicable, to the lowest point of the boiler.
b) For locomotive, vertical and marine type boilers, the valve or cock shall be

attached direct to the boiler or to a suitable pad or stand pipe. For water tube boilers the valve or cock shall be outside the brickwork with a substantial steel pipe between it and the mudbox.

c) For Cornish and Lancashire boilers the cock or valve may be attached to a cast steel elbow pipe of substantial section bolted to a suitable stand pipe or pad riveted to the boiler. But cast iron elbow pipes shall not be permitted.


Reg. 319

Blow-down Valve or Cock

a) Each valve or cock shall be fitted with a device which shall indicate clearly its open and closed positions, and any key or similar device for operating the valve or cock shall be such that it cannot be removed unless the valve or cock is fully closed.
b) The locking feather shall be secured by welding.
c) Cocks fitted with taper plugs shall be of the bolted cover type with separate packing glands.


Reg. 320
WATER GAUGES

a) Every boiler shall have two means of indicating the water in it of which one shall be conventional gauge glass:

Provided that in the case of boiler drums below 3 feet (91 cm) diameter where there is difficulty in fitting two water gauges, two test cocks and a glass water gauge shall be fitted.
b) The lowest visible part of the glass of the water gauge and lower test cock shall be fixed at safe working level. For locomotive type and vertical boilers this shall not be less than 50 millimetres above the highest part of the firebox roof plate.

Minimum length of the visible portion of the gauge glasses shall be 200 mm. The length may be increased depending upon the capacity of the boiler by the Chief Inspector/Director of boiler of the manufacturing State.
c) Glass water gauges shall be so placed as to be easily seen and reached by the boiler attendant. The fittings of glass water gauges and test cocks shall be of substantial make with large passage ways through them to facilitate cleaning. The gauge cocks when open shall have their handles in a vertical direction and each handle at its junction with the plug shall be plainly marked with a deep line to indicate the direction of the passage way through the plug. When detachable handle are provided arrangement shall be made to prevent incorrect fitting of the handles.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
548
PDF page index
548 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 6d4995a8906b947e
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 63, Regulation 63, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.548. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.