Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 276 — General
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 277. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
|
| ||||||||||||||||||||||||||||||||
Reg. 277
| ||||||||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
General
The thickness T specified in equation 74 of Regulation 278 is the thickness of the end plate after manufacture and is applicable over the whole area of the end plate up to the point where, for ends of partially spherical shape, the dishing radius joins the corner radius; from this point a gradual thinning is permissible up to maximum of 10 per cent of the thickness T at the point where the corner radius joins the straight portion of flanged end plate. A similar gradual thinning is permissible for end plates of semi-ellipsoidal shape. This permissible reduction in thickness applies also to the flange for the manhole opening. In no case, however, when the end plate is but welded to the drum shell, shall the thickness of the edge of the flange for connection to the shell be less than the thickness of an unpierced seamless shell of the same diameter and material, determined by equation 72.
Possible IBR 2026 successors (heading match, unverified): Reg. 3, Reg. 63, Reg. 142, Reg. 165, Reg. 175, Reg. 191, Reg. 293, Reg. 335, Reg. 358, Reg. 396