Indian Boiler Regulations, 2026 · Chapter 2 · Materials of Construction
Regulation 33. Rolling margin for carbon steel
Not yet checked against the official Gazette; verify before relying on it.
33. Rolling margin for carbon steel. ─No plate or rolled section shall be under the specified thickness at any part, nor more than five per cent over the calculated weight, except that in the case of thin plates and wide plates the weight tolerances shall be as per Table 2/3 mentioned below:
Table 2/3: Schedule of percentage of rolling weight tolerances for boiler plates
Width in millimetre(mm)
| Serial No. | Thickness in mm | Under 1219 | 1219 to under 1524 | 1524 to under 1828 | 1828 to under 2134 | 2134 to under 2438 | 2438 to under 2743 | 2743 to under 3048 | 3048 to under 3352 | 3352 and over |
| % | % | % | % | % | % | % | % | % | ||
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | (11) |
| 1. | 6 to under 8 | 5 | 5 | 5 | 7 | 9 | 12 | - | - | - |
| 2. | 8 to under 10 | 5 | 5 | 5 | 6 | 7.5 | 10 | 11 | 12 | - |
| 3. | 10 to under 11 | 5 | 5 | 5 | 6 | 6 | 8 | 9 | 11 | 15 |
| 4. | 11 to under 13 | 5 | 5 | 5 | 5 | 6 | 7.5 | 8 | 9 | 12 |
| 5. | 13 to under 16 | 5 | 5 | 5 | 5 | 6 | 6 | 7.5 | 9 | 10 |
| 6. | 16 to under 19 | 5 | 5 | 5 | 5 | 5 | 5 | 7 | 8 | 9 |
| 7. | 19 to under 25 | 5 | 5 | 5 | 5 | 5 | 5 | 6 | 7 | 8 |
| 8. | 25 to under 51 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 9 | 7 |
Table structure read from the Gazette PDF, page 518. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Serial Thickness in Under 1219 to 1524 to 1828 to 2134 2438 to 2743 to 3048 to 3352
No. mm 1219 under under under and
under under under to 2743 3048 3352 over
1524 1828 2134 under
2438
% % % % % % % % %
(1) (2) (3) (4) (5) (6) (7) (8) (9) (10) (11)
1. 6 to under 8 5 5 5 7 9 12 - - -
2. 8 to under 10 5 5 5 6 7.5 10 11 12 -
3. 10 to under 11 5 5 5 6 6 8 9 11 15
4. 11 to under 13 5 5 5 5 6 7.5 8 9 12
5. 13 to under 16 5 5 5 5 6 6 7.5 9 10
6. 16 to under 19 5 5 5 5 5 5 7 8 9
7. 19 to under 25 5 5 5 5 5 5 6 7 8
8. 25 to under 51 5 5 5 5 5 5 5 9 7Note: All the above margins will be taken over net theoretical weight.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
No carbon steel plate or rolled section may be under the specified thickness at any part, nor more than five per cent over the calculated weight.
Key points
- For thin plates and wide plates, the weight tolerances in Table 2/3 apply instead. The table gives percentages by thickness band (in mm) and width band (in mm). See the Official text tab for the values.
- The margins are taken over the net theoretical weight.
Watch out
- The under-thickness rule has no tolerance: no part may be under the specified thickness.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 12 | Rolling Margin | 100% | Chapter II (DPIIT scan), image 1 |
IBR 1950 regulation 12 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 12 page for its amendments.
| Reg. 12 MATERIALS OF CONSTRUCTION STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL |
| No plate or rolled section shall be under the specified thickness at any part, nor more than 5 per cent over the calculated weight, except that in the case of thin plates and wide plates the weight tolerances shall be as set out in the table below: Schedule of percentage of Rolling weight tolerances for boiler plates
All the above margins will be taken over nett theoretical weight. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||