65. Dimension of test bars.─ (1) (a)The Transverse test bars of the diameter specified by the Inspecting Authority according to the main cross-sectional thickness of the casting represented, shall conform to the following dimensions, namely:-

Table 2/38

Serial No.Diameter test BarLimits on DiameterOverall lengthMain cross-sectional thickness of casting represented
(1)(2)(3)(4)(5)
1.mmmm.mm.mm.
2.15+ 1254Not Exceeding 10
3.22+ 1.7381Over 10 and not exceeding 19
4.30+ 2533Over 19 and not exceeding 28
5.40+ 2.5533Over 28 and not exceeding 41
6.53+ 2.5685Over 41

Table structure read from the Gazette PDF, page 549. Verification status as for the text above.

(b)Bars cast to a size in excess of the limits given above may be machined to a diameter within the specified

Show original extracted text (diagnostic, not authoritative)
Serial No. Diameter test Bar  Limits on  Overall length Main cross-sectional thickness of

                              Diameter                   casting represented

(1)                   (2)     (3)                (4)              (5)

1.                    mm      mm.                mm.              mm.

2.                    15      + 1                254     Not Exceeding 10

3.                    22      + 1.7              381     Over 10 and not exceeding 19

4.                    30      + 2                533     Over 19 and not exceeding 28

5.                    40      + 2.5              533     Over 28 and not exceeding 41

6.                    53      + 2.5              685     Over 41

(b)Bars cast to a size in excess of the limits given above may be machined to a diameter within the specified
limits.

(c)Bars cast within these limits of diameter may also be machined before the transverse test is made, providing that the finished diameter falls within these limits.

(2)The tensile test bars of the diameter specified by the Inspecting Authority, according to the main cross-sectional thickness of the casting represented shall conform to the dimensions shown in the Table 2/39. Bars may be tested with either plain or screwed ends.

TABLE 2/39

Serial No.Diameter as CastGauge diameterAreaMin. parallel lengthMin. radiusMin. Length of plain endsScrewed endsApproximate minimum overallMain cross- sectional thickness of casting represented
(1)(2)(3)(4)(5)(6)(7)(8)(9)(10)
1.BDAPRCEFLPLS
2.mm.mm.Sq.m
m.
mm.mm.mm.mm.mm.mm.mm.mm.
3.15108025383813 S.P.
14 S.F.
14 S.W
141143Not exceeding
10
4.221416150893819 S.F.
22 S.W.
1917937Over 10 and not
exceeding 19
5.302032250895038 S.F.
38 S.W
38210149Over 19 and not
exceeding 38
6.412964550896338 S.F
38 S.W.
38229184
184
Over 38 and not
exceeding 41
7.5341129050898950 S.F51286210Over 41

Table structure read from the Gazette PDF, page 550. Verification status as for the text above.

Show original extracted text (diagnostic, not authoritative)
Serial No. Diameter Gauge Area      Min.     Min.   Min.       Screwed ends     Approximate minimum  Main cross- sectional
                 as Cast diameter  parallel  radiu                                       overall      thickness of casting
                                    length          Length of
                                               s                                                           represented
                                      (5)           plain
                                      P       (6)                                                              (10)
                                               R    ends

(1)  (2)  (3)  (4)                                  (7)                (8)           (9)

1.   B    D    A                                    C          E            F   LP        LS

2.   mm.  mm. Sq.m                 mm.       mm. mm.           mm.          mm. mm.       mm.               mm.

               m.                                                                                    Not exceeding
                                                                                                             10
3.   15   10   80                  25        38     38         13 S.P.      14  114       3
                                                                                                     Over 10 and not
                                                               14 S.F.                                exceeding 19

                                                               14 S.W                                Over 19 and not
                                                                                                      exceeding 38
4.   22   14   161                 50        89     38         19 S.F.      19  179       37
                                                                                                     Over 38 and not
                                                               22 S.W.                                exceeding 41

5.   30   20   322                 50        89     50         38 S.F.      38  210       149            Over 41

                                                               38 S.W

6.   41   29   645                 50        89     63         38 S.F       38  229       184

                                                               38 S.W.                    184

7.   53   41   1290                50        89     89         50 S.F       51  286       210

The test bars shall be cast as parallel bars of the diameters given in column B and then machined to the dimensions C and P in the Table 2/39.

Fig. 2/1

(3)For castings of over 51 mm in thickness, a test bar of diameter larger than 53 mm may be used by agreement between the manufacturer and the Inspecting Authority. For diagram and table see Fig.2/1 and Table 2/39 under sub-regulation (2) of this regulation.

Parts of this extracted text look garbled; read the Gazette page before using any value.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Figures cited in this regulation (1, exact crops of the Gazette)

Gazette Fig. 2/1
Fig. 2/1(no caption printed with this figure)
View Gazette page 551 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 65 sets the dimensions of transverse and tensile test bars for grey iron castings. The bar diameter is chosen by the Inspecting Authority according to the main cross-sectional thickness of the casting.

Key points

  • (1)(a) Table 2/38 gives, for each transverse bar diameter, the diameter limits, overall length and the range of casting thickness it represents.
  • (1)(b) Bars cast oversize may be machined to a diameter within the limits.
  • (1)(c) Bars cast within the limits may also be machined before the test, provided the finished diameter stays within the limits.
  • (2) Table 2/39 and Fig. 2/1 give the tensile bar dimensions (gauge diameter, area, parallel length, radius, end details and overall length) for each as-cast diameter. Bars may have plain or screwed ends. They are cast as parallel bars of the column B diameter and then machined to dimensions C and P.
  • (3) For castings over 51 mm thick, a bar larger than 53 mm in diameter may be used by agreement between the manufacturer and the Inspecting Authority.

Watch out

  • The extracted Table 2/39 is badly misaligned. Use the Official text tab and the Gazette page for the exact values.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
507Test bars100%Chapter XI (DPIIT scan), image 2
IBR 1950 regulation 507 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 507 page for its amendments.


Reg. 507, Reg. 508
STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

CAST IRON, TUBES AND HEADERS

Test bars

For all new economisers the hydraulic test must be applied as shown below:-

a) When the test bars are cast separately, they shall be poured at the same time and from the same ladle of metal as the casting or castings they represent. The number of test bars specified in Regulation 508 shall be applicable to all castings of each melt.
b) when the bars are cast on the mould for the castings and the mould for the test piece shall be joined together in such a manner that the liquid metal fills both moulds at the same operation.
c) all test bars shall be cast in green sand or in loam or dry sand moulds according as to whether the casting or castings they represent are moulded in green sand, or in loam or dry sand respectively.
d) The test bars shall not be subjected to any heat treatment after leaving the moulds except where the castings are heat-treated.



Reg. 508
STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

CAST IRON, TUBES AND HEADERS

Number of tensile tests

(a) The number of tests required for each batch of castings shall be in accordance with the following table the various classes of castings being divided into 4 representative groups:-

Group Weight of castings Test requirements
1. Up to 28 lbs One test for each 30 cwts. Of castings or part thereof.


One test for each 2 tons of castings or part thereof.

2. Over 28 lbs. and up to 1 cwt
3. Over 1 cwt. And up to 1 ton One test for each 3 tons of castings or part thereof.
 

In the above Group 1, 2 and 3, all castings represented by one test must be poured from the same ladle of same heat as the bar or bars provided for the test.

4. Over 1 ton and important castings One test for each 4 tons of castings or part thereof or for each casting weighing 4 tons or more.

(b) Conditions for Acceptance and for Rejection:-

Test Result Conclusion
1st Pass The batch or separate casting represented shall be accepted.
Tensile or Transverse test fails Two more tests shall be made.
2nd If both pass
If  either fails 
The batch or separate casting represented shall be accepted.
The batch or separate castings represented shall be rejected.

Provided always that, in the case of failure of any test piece showing obvious casting defects, another test piece shall be taken from spare test bars or cut from a casting from the same batch and the results obtained from this substituted for those obtained from the defective test bars.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
549–551
PDF page index
549–551 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash a5548f844694ba7a
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 65, Regulation 65, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.549–551. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.