Indian Boiler Regulations, 2026 · Chapter 2 · Materials of Construction
Regulation 65. Dimension of test bars
Not yet checked against the official Gazette; verify before relying on it.
65. Dimension of test bars.─ (1) (a)The Transverse test bars of the diameter specified by the Inspecting Authority according to the main cross-sectional thickness of the casting represented, shall conform to the following dimensions, namely:-
Table 2/38
| Serial No. | Diameter test Bar | Limits on Diameter | Overall length | Main cross-sectional thickness of casting represented |
|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) |
| 1. | mm | mm. | mm. | mm. |
| 2. | 15 | + 1 | 254 | Not Exceeding 10 |
| 3. | 22 | + 1.7 | 381 | Over 10 and not exceeding 19 |
| 4. | 30 | + 2 | 533 | Over 19 and not exceeding 28 |
| 5. | 40 | + 2.5 | 533 | Over 28 and not exceeding 41 |
| 6. | 53 | + 2.5 | 685 | Over 41 |
Table structure read from the Gazette PDF, page 549. Verification status as for the text above.
(b)Bars cast to a size in excess of the limits given above may be machined to a diameter within the specified
Show original extracted text (diagnostic, not authoritative)
Serial No. Diameter test Bar Limits on Overall length Main cross-sectional thickness of
Diameter casting represented
(1) (2) (3) (4) (5)
1. mm mm. mm. mm.
2. 15 + 1 254 Not Exceeding 10
3. 22 + 1.7 381 Over 10 and not exceeding 19
4. 30 + 2 533 Over 19 and not exceeding 28
5. 40 + 2.5 533 Over 28 and not exceeding 41
6. 53 + 2.5 685 Over 41
(b)Bars cast to a size in excess of the limits given above may be machined to a diameter within the specified
limits.(c)Bars cast within these limits of diameter may also be machined before the transverse test is made, providing that the finished diameter falls within these limits.
(2)The tensile test bars of the diameter specified by the Inspecting Authority, according to the main cross-sectional thickness of the casting represented shall conform to the dimensions shown in the Table 2/39. Bars may be tested with either plain or screwed ends.
TABLE 2/39
| Serial No. | Diameter as Cast | Gauge diameter | Area | Min. parallel length | Min. radius | Min. Length of plain ends | Screwed ends | Approximate minimum overall | Main cross- sectional thickness of casting represented | ||
|---|---|---|---|---|---|---|---|---|---|---|---|
| (1) | (2) | (3) | (4) | (5) | (6) | (7) | (8) | (9) | (10) | ||
| 1. | B | D | A | P | R | C | E | F | LP | LS | |
| 2. | mm. | mm. | Sq.m m. | mm. | mm. | mm. | mm. | mm. | mm. | mm. | mm. |
| 3. | 15 | 10 | 80 | 25 | 38 | 38 | 13 S.P. 14 S.F. 14 S.W | 14 | 114 | 3 | Not exceeding 10 |
| 4. | 22 | 14 | 161 | 50 | 89 | 38 | 19 S.F. 22 S.W. | 19 | 179 | 37 | Over 10 and not exceeding 19 |
| 5. | 30 | 20 | 322 | 50 | 89 | 50 | 38 S.F. 38 S.W | 38 | 210 | 149 | Over 19 and not exceeding 38 |
| 6. | 41 | 29 | 645 | 50 | 89 | 63 | 38 S.F 38 S.W. | 38 | 229 | 184 184 | Over 38 and not exceeding 41 |
| 7. | 53 | 41 | 1290 | 50 | 89 | 89 | 50 S.F | 51 | 286 | 210 | Over 41 |
Table structure read from the Gazette PDF, page 550. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Serial No. Diameter Gauge Area Min. Min. Min. Screwed ends Approximate minimum Main cross- sectional
as Cast diameter parallel radiu overall thickness of casting
length Length of
s represented
(5) plain
P (6) (10)
R ends
(1) (2) (3) (4) (7) (8) (9)
1. B D A C E F LP LS
2. mm. mm. Sq.m mm. mm. mm. mm. mm. mm. mm. mm.
m. Not exceeding
10
3. 15 10 80 25 38 38 13 S.P. 14 114 3
Over 10 and not
14 S.F. exceeding 19
14 S.W Over 19 and not
exceeding 38
4. 22 14 161 50 89 38 19 S.F. 19 179 37
Over 38 and not
22 S.W. exceeding 41
5. 30 20 322 50 89 50 38 S.F. 38 210 149 Over 41
38 S.W
6. 41 29 645 50 89 63 38 S.F 38 229 184
38 S.W. 184
7. 53 41 1290 50 89 89 50 S.F 51 286 210The test bars shall be cast as parallel bars of the diameters given in column B and then machined to the dimensions C and P in the Table 2/39.
Fig. 2/1
(3)For castings of over 51 mm in thickness, a test bar of diameter larger than 53 mm may be used by agreement between the manufacturer and the Inspecting Authority. For diagram and table see Fig.2/1 and Table 2/39 under sub-regulation (2) of this regulation.
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
Figures cited in this regulation (1, exact crops of the Gazette)

View Gazette page 551 · figure catalogue
Auto-traced outline: SVG · DXF (not to scale, may copy print defects)
In short
Regulation 65 sets the dimensions of transverse and tensile test bars for grey iron castings. The bar diameter is chosen by the Inspecting Authority according to the main cross-sectional thickness of the casting.
Key points
- (1)(a) Table 2/38 gives, for each transverse bar diameter, the diameter limits, overall length and the range of casting thickness it represents.
- (1)(b) Bars cast oversize may be machined to a diameter within the limits.
- (1)(c) Bars cast within the limits may also be machined before the test, provided the finished diameter stays within the limits.
- (2) Table 2/39 and Fig. 2/1 give the tensile bar dimensions (gauge diameter, area, parallel length, radius, end details and overall length) for each as-cast diameter. Bars may have plain or screwed ends. They are cast as parallel bars of the column B diameter and then machined to dimensions C and P.
- (3) For castings over 51 mm thick, a bar larger than 53 mm in diameter may be used by agreement between the manufacturer and the Inspecting Authority.
Watch out
- The extracted Table 2/39 is badly misaligned. Use the Official text tab and the Gazette page for the exact values.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 507 | Test bars | 100% | Chapter XI (DPIIT scan), image 2 |
IBR 1950 regulation 507 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 507 page for its amendments.
|
CAST IRON, TUBES AND HEADERS | ||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||
|
CAST IRON, TUBES AND HEADERS | ||||||||||||||||||||||||||||||
| ||||||||||||||||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 65, Regulation 65, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.549–551. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.