Indian Boiler Regulations, 2026 · Chapter 11 · Standard Conditions for the Design and Construction of Economisers, Feed Pipes, Feed Heaters and Other Similar Vessels
Regulation 375. Bolts, studs joints and Flanges
Not yet checked against the official Gazette; verify before relying on it.
375. Bolts, studs joints and Flanges.─ (1) The maximum allowable working pressure for the bolts shall as per the following formula, ─
2
N x C 1.28
P = ------- D - -------- Equation (11/1)
A n
Where,
N = No. of bolts securing the parts,
n = No. of screws threads per inch,
D = Bolt diameter in inches measured over the threads,
A = The area exposed to pressure which is assumed to be bounded by a line midway between the pitch line of the bolts and the inner edge of the flange where flat joints are used with joints rings. Where conical joints faces are used with joint rings, of curvilinear cross-section, the area exposed to pressure shall be assumed to extend to the root of the thread where the tube ends are screwed, or to a corresponding boundary if the flanges are attached by other means. C = 4,700 for steel bolts or studs of 28 tons/sq.in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch,
C = 5,100 for steel bolts or studs of 30 tons /sq. in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch.
C = 5,600 for steel bolts or studs of 35 tons /sq. in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch.
C = 5,600 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is not less than 3/4 inch and not greater than 7/8 inch.
C = 7,000 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is greater than 7/8 inch.
Where the bolts or studs used have a tensile strength exceeding 32 tons sq. in., a plate shall be permanently fixed to the economiser structure in a prominent position drawing attention to this fact in case replacements of bolts or studs are necessary. In no case shall the nuts be exposed to the action of the flue gases.
(2)The thickness of each flange shall be not less than that given by the following equation:
t = [P.D. (D1 - D)] Equation (11/2)
Where, ------------------
2
t = Thickness of flange in thirty-seconds of an inch.
P = Maximum Allowable Working pressure, in lbs. per square inch (gauge)
D = Outside diameter of the tube in inches.
D1 = Pitch circle diameter or bolts or studs in inches.
Provided that such flange is cast integral with the body and with the appropriate internal corner radius. In no case, however, the thickness of a flange shall be less than 24 thirty -seconds of an inch.
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 375 gives the formulae for the maximum allowable working pressure of economiser joint bolts and studs, and for the minimum flange thickness. Both use inch-based units.
Key points
- (1) Equation (11/1) gives the pressure P from N (number of bolts), n (screw threads per inch), D (bolt diameter over the threads, in inches), A (area exposed to pressure) and a constant C.
- The text defines how A is bounded for flat joints with joint rings and for conical joint faces with curvilinear rings.
- C depends on the bolt or stud's minimum ultimate tensile stress and its diameter over the thread. Take the values from the Official text tab.
- (2) Equation (11/2) gives the flange thickness t in thirty-seconds of an inch, from P (in lbs. per square inch gauge), D (tube outside diameter) and D1 (pitch circle diameter of the bolts or studs).
Watch out
- Where bolts or studs have a tensile strength exceeding 32 tons per sq. in., a plate must be permanently fixed in a prominent position on the economiser structure to draw attention to this when bolts or studs are replaced.
- Nuts must never be exposed to the flue gases.
- The flange equation applies where the flange is cast integral with the body with the appropriate internal corner radius. No flange may be thinner than 24 thirty-seconds of an inch.
- Both equations are garbled in the extracted text. Check the Gazette page for their exact form.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 208 | Bolts and Studs | 100% | Chapter IV (DPIIT scan), image 8 |
| 410 | Flanges | 100% | Chapter X (DPIIT scan), image 4 |
IBR 1950 regulation 208 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 208 page for its amendments.
| Reg. 208 STAYS Bolts and Studs
|
IBR 1950 regulation 410 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 410 page for its amendments.
| Reg. 410, Reg. 411, Reg. 412
Reg. 411
Reg. 412
|
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 375, Regulation 375, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.748–749. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.