25. Procedure for recognition of Competent Person.─

(1)(a) This regulation provides requirements for the uniform qualification, examination, issuance and renewal of Central Boiler Boards authorisation to competent persons under the Act for inspection and certification of boilers and boiler components during manufacture, erection, operation and maintenance throughout India.

(2)Minimum qualifications and experience required are as under.─

(a)shall be a graduate in Mechanical Engineering or Production or Power Plant or Metallurgical Engineering from a recognised institute;

(b)minimum five years’ experience singly or cumulatively in the following fields related to boilers:-

(i)Design;

(ii)Manufacture;

(iii)Commissioning;

(iv)Operation and maintenance;

(v)Inspection and certification during manufacture or operation and maintenance;

(vi)High Pressure Welding-Inspection;

(c)Level-II NDT Certificates from Indian Society for Non-Destructive Testing (ISNT) or American Society for Non-Destructive Testing (ASNT) or any other professional body recognised by ISNT or ASNT in Non-Destructive methods of testing in radiography and ultrasonic testing.

(3)Central Boilers Board Examination Standing Committee Composition: -(a)For the purpose of these regulations, the Central Boilers Board constitutes the ‘Central Boilers Board Examination Standing

Committee’ consisting of the following persons-

(i)Technical adviser (Boilers) -- Chairperson

(ii)Two Chief Inspectors or Directors of Boilers from States -- Members

(iii)Two Members from Board representing Central Government or Bureau of Indian Standards or

Boiler and boiler component manufacturers or National Laboratories or Engineering Consultancy agencies or user of boilers and other interests - Members

(b)Secretary, Central Boilers Board shall nominate the members;

(4)The Process for Central Boilers Board Examination shall be as under─

(a)an examination shall be conducted by the Central Boilers Board Examination Standing Committee or an agency or Regional Examination Standing Committees authorised by it, as per the following examination methods, namely: -

(i)written examination consisting of design, manufacture, operation and maintenance of the boiler, Non

Destructive Testing Techniques, inspection and certification of boilers during manufacture and use as per these regulations (70% weightage);

(ii)candidate shall be required to secure at least 45% marks in each written examination papers and at least 60% marks in aggregate to qualify for viva-voce;

(iii)viva-voce on the above (30% weightage);

(iv)the candidate shall secure at least 60% marks in aggregate (written exam with 70% weightage and viva-voce with 30% weightage) in order to pass the examination;

(v)the Central Boilers Board shall issue a passing grade certificate to the candidate after passing the examination;

(b)application for appearing in the Central Boiler Board Examination shall be made in the format as provided by the Central Boilers Board Examination Standing Committee at such place and time as decided by the Central Boilers Board Examination Standing Committee or an agency or Regional Examination Standing Committees authorised by it.

(5)The process for Central Boilers Board authorisation shall be as under: ─

(a)the Competent Person shall perform the work without conflict of interest;

(b)an applicant for a Central Boiler Board Authorisation shall meet the following requirements, namely:-

(i)the applicant shall be in regular employment of, and exclusively engaged by a Central Boilers Board recognised Inspecting Authority:

Provided that for inspection and certification of boilers during use under section 13 of the Act, the applicant can work independently also without taking employment with the Central

Boilers Board recognised Inspecting Authority ;

(ii)the applicant shall meet the minimum qualification and experience requirements as referred in sub-

regulation (2) of this regulation;

(iii)the applicant shall have taken and passed the Central Boilers Board examination as referred to in sub-regulation (4) of this regulation;

(iv)the applicant shall apply for an authorisation not later than three years after passing the Central

Boilers Board Examination and a person whose authorisation has not been issued within the three year period shall be required to take the Central Boiler Board Examination and receive a passing grade; and

(v)the maximum age for the Competent Person shall be sixty-five years provided the person is medically fit;

(c)(i) when the applicant meets the requirements as referred to in clause (b)and at the request of the applicant’s employer; a Central Boilers Board authorisation card and a certificate shall be issued:

Provided that the request for authorisation card, only for undertaking inspection and certification of boilers during use, under section 13 of the Act, may also be made by the applicant;

(ii)the application for an authorisation shall be on forms available with the Central Boilers Board; and

(iii)a Competent Person may possess only one valid authorisation card;

(d)(i) the validity of an authorisation certificate shall be three years from the date of issue or in co-terminus with the validity period of recognition of employing Inspecting Authority (wherever applicable), whichever is earlier;

(ii)for undertaking inspection and certification of boilers during manufacture and erection, the Competent Person must be in regular employment of the Central Boilers Board recognised Inspecting Authority failing which the authorisation lapses;

(iii)Where the Competent Person leaves the employment, Central Boilers Board Authorisation Card shall be surrendered by the Inspecting Authority to the Secretary, Central Boilers Board within a period of seven days from the date of such leaving;

(iv)the request for renewal shall be made by the Competent Person’s employer and the request shall certify that the Competent Person maintained inspection proficiency by performing or supervising inspection activity and that the individual has met the continuing updation requirement as laid down in sub-clause (vi):

Provided that request for renewal of authorisation, only for undertaking inspection and certification of boilers during use under section 13 of the Boilers Act, 2025, can also be made by the Competent Person, giving details of inspections undertaken in the last three years, and confirming that he has met the continuing updation requirement as given in clause (vi) of this sub-regulation;

(v)on change of employment, a request for authorisation card shall be made by the Competent Person’s current employer on forms obtained from the Central Boilers Board;

(vi)each Central Boilers Board authorised Competent Person, at least once every three years, shall either attend a Central Boilers Board seminar or receive other instruction related to inspections and the instruction may be in any format, e.g., classroom, home study, or web-based; the topics may include any subject of relevance to the inspection process, such as new methods, products, materials, technology or changes to construction or repair codes;

(vii)a person whose authorisation has not been renewed for five years or less may, on proper application, shall have the authorisation reinstated;

(viii)the employer or Competent Person, if working independently, as the case may be, shall provide verification of continuing updation as mentioned in sub-clause (vi); and

(ix)a person whose authorisation has not been renewed for more than five years shall be required to qualify the examination conducted by Central Boilers Board;

(e)

(i)a Central Boilers Board authorisation may be revoked by the Secretary, Central Boilers Board on the ground of falsification of any statement contained in any application;

(ii)when an evaluation reveals that a Competent Person authorised by Central Boilers Board is found negligent in his duty or made false statements on forms used for documentation of his duties, a Central Boilers Board Committee formed for the purpose may examine the evaluation and recommend to the Secretary, Central Boilers Board, a suitable action against such Competent Person and the Secretary, Central Boilers Board shall take the decision;

(iii)if any person is aggrieved by a decision of the Secretary, Central Boilers Board, he may prefer an appeal against such decision to the Central Boilers Board within thirty days from the date of communication of the decision;

(iv)the decision of the Central Boilers Board shall be binding; and

(v)any person aggrieved by,-
(A) an order made or purporting to be made by a Competent Person in the exercise of any power conferred by or under the Act; or

(B) a refusal of a Competent Person to make any order or to issue any certificate which he is required or enabled by or under the Act to make or issue ,
may, within thirty days from the date on which such order or refusal is communicated to him, prefer an appeal against such order or refusal, to the Chief Inspector of Boilers of the State in which the boiler is located;

(C) fees for each authorisation issued, renewed or reinstated fixed by the Central Boiler Board examination standing committee shall be paid including through electronic mode.

(6)The Central Boilers Board authorisation number for the purpose of its usage shall be recorded on all forms used by him and on the items inspected and stamped as a proof of inspection and the authorisation number shall also be entered into the Competent Person’s diary and other relevant records.

(7)(a) A diary shall be maintained by the Competent Person for,-

(i)inspection of construction activities; and

(ii)in-service inspection including repairs and alterations for each location or site as per the format laid down by the Central Boilers Board;

(b)the diary shall be bound and numbered and the purpose of the diary shall be to provide a record of the Competent Person’s activity and to support the continuity of inspections;

(c)the Competent Person’s diary shall be the property of the employer Inspecting Authority, wherever applicable, and shall be available at the location or site of the inspection; and

(d)the diary shall be maintained for a minimum period of five years from the date of last entry and it may also be maintained in digitised form with provision for online entries:-

(8)Duties and responsibilities of a Competent Person shall include the following, namely:-

(a)on receipt of an application for renewal of certificate for use of a boiler, the Competent Person shall, within fifteen days from the date of such receipt inspect the boiler on a date communicated to the owner in advance;

(b)a copy of memorandum of inspection book shall be obtained from the concerned boiler inspectorate though the Inspecting Authority or directly, if working independently, for in-service boilers which shall be returned within a period of seven days from the date of completion of final inspection for making necessary entries therein;

(c)the Competent Person shall also discharge the following duties at various stages, namely:-

(i)Inspection during manufacture and commissioning:-

(A) work to the satisfaction of the Inspecting Authority for inspection during manufacture, erection and commissioning of boilers as per the provisions of these regulations;

(B) Inspect during manufacture and erection as per the procedure given in Appendix-A;

(ii)In – service inspection:-
(A) verify whether the stamping or nameplate is legible and represents the item described on the inspection documentation;

(B) perform external and internal inspection and witness any required pressure tests;

(C) report the inspection results, including any nonconforming conditions to the owner of the boilers;

(iii)Repairs and alterations:-

(A) verify that the boiler owner has informed the chief inspector in writing and the activity is permitted under the scope of the certificate or the structural alteration, addition or renewal is made under his supervision;

(B) verify that the boiler repairer has a valid certificate as specified under these regulations;

(C) monitor the quality control system and verify the system is being implemented as required by regulations;

(D) verify that all materials comply with these regulations;

(E) verify that all welding procedure specifications, procedure qualification records, and welder and welding operation records conform to these regulations;

(F) verify that heat treatments as required under these regulations have been performed and properly documented;

(G) verify that non-destructive examinations and tests as required under these regulations have been performed and properly documented;

(H) witness pressure tests as required under these regulations;

(I) verify that information in the forms is correct and that the details have been properly punched;

(J) verify the correctness of the stamping;

(9)Competent Person or Inspecting Authority may charge a fee for the inspection subject to the condition that the fee shall not be less than the fee specified by the concerned State.

(10)Inspection shall be carried out as provided under these regulations and the relevant certificate shall be issued as follows, namely:-

(a)For in-service Boilers inspection: -

(i)one copy shall be given to the owner of the boiler on the day of inspection;

(ii)one copy shall be given to the Chief Inspector along with the Memorandum of Inspection Book (Form-XI);

(iii)one copy shall remain in Book.

(iv)In case inspection is not carried out as provided under these regulations, the Chief Inspector of Boilers shall report the matter to the Secretary, Central Boilers Board for appropriate action against the Competent Person which may include cancellation of his authorisation.

(b)For inspection during manufacture: -

(i)one copy shall be given to the manufacturer;

(ii)one copy shall remain with the Inspecting Authority.

(c)For inspection during erection:-

(i)one copy shall be given to the owner of the boiler;

(ii)one copy shall be given to the Chief Inspector;

(iii)one copy shall remain with the Inspecting Authority.

Referenced provisions

Act s.13 · Appendix A · Form-XI

Independent explanation — not the law · draft · engineer review in progress

In short

Regulation 25 is the full scheme for Competent Persons: qualifications, the Central Boilers Board examination, the authorisation card, its validity and renewal, the diary, duties, fees and how inspection certificates are distributed.

Key points

  • (2) Eligibility. A graduate in Mechanical, Production, Power Plant or Metallurgical Engineering; at least five years' experience, singly or cumulatively, in boiler design, manufacture, commissioning, operation and maintenance, inspection and certification, or high pressure welding inspection; and Level-II NDT certificates (ISNT, ASNT or a body they recognise) in radiography and ultrasonic testing.
  • (3) Examination Standing Committee. Technical adviser (Boilers) as Chairperson, two Chief Inspectors or Directors of Boilers, and two Board members.
  • (4) Examination. Written papers (70% weightage) and viva-voce (30% weightage). You need at least 45% in each written paper and 60% in aggregate to reach the viva-voce, and 60% in aggregate overall to pass.
  • (5)(b) Authorisation. The applicant must be in regular, exclusive employment of a recognised Inspecting Authority, meet (2), have passed the examination, and apply within three years of passing. Exception: for inspection and certification of boilers during use under section 13 of the Act, a Competent Person may work independently, without such employment. The maximum age is sixty-five years, if medically fit.
  • (5)(c)–(d) Card and validity. Issued at the employer's request; only one valid card per person. Valid for three years from issue or until the employing Inspecting Authority's recognition expires, whichever is earlier. Renewal requires continuing updation at least once every three years (seminar or other instruction).
  • (6)–(7) Records. The authorisation number goes on all forms and stamped items. A bound, numbered diary is kept for at least five years from the last entry; it may be digitised.
  • (8) Duties. Inspect a boiler within fifteen days of receiving a renewal application; return the memorandum of inspection book within seven days of final inspection; inspect during manufacture and erection per Appendix-A; carry out in-service inspections; verify repairs and alterations (materials, welding records, heat treatment, NDT, pressure tests, stamping).
  • (9) Inspection fees may not be less than the fee specified by the State.
  • (10) Sets who receives copies of certificates for in-service, manufacture and erection inspections.

Watch out

  • For inspection of boilers in use under section 13 of the Act, a Competent Person may work independently and may apply or seek renewal personally.
  • For manufacture and erection work, the authorisation lapses if regular employment with a recognised Inspecting Authority ends. The card must be surrendered within seven days of leaving.
  • Not renewed for five years or less: may be reinstated on application. More than five years: the examination must be passed again.
  • Authorisation may be revoked for falsified applications. Separately, if an evaluation finds a Competent Person negligent in duty or making false statements on documentation forms, a Central Boilers Board committee may examine it and recommend action to the Secretary. Appeals against the Secretary's decision go to the Board within thirty days; appeals against a Competent Person's order or refusal go to the State's Chief Inspector within thirty days.
  • If inspection is not carried out as the regulations provide, the Chief Inspector reports it to the Secretary, Central Boilers Board, and action may include cancellation of the authorisation.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

No candidate heading found in the historical print edition.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
505–510
PDF page index
505–510 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash c2c330d394985b6d
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 25, Regulation 25, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.505–510. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.