Regulation 571. Bolts and Studs

Official text — not yet verifiedGazette 1 Oct 2026 · printed p. 862Formula / symbols

Not yet checked against the official Gazette; verify before relying on it.

Reproduced from the Gazette of India · verification status above

571. Bolts and Studs .─(1) Bolts and studs connecting the parts of the vessel such as shell, end plates , tube plates shall be made of steel.

(2)The maximum working pressure for the bolts and studs shall be as per by the following Equation,─

        N x C     1.28 2

P =     --------  D - -----                                      Equation (16/1)

        A         n

Where,

PMaximum allowable working pressure in tons/sq.in,
Dis the diameter of bolt or stud over threads in inches,
Nis the number of bolts or studs securing the part,
nis the number of threads of screws per inch,
C4,700 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is less than 19 mm,
C5,100 for steel bolts or studs of 30 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is less than 19 mm,
C5,600 for steel bolts or studs of 35 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is not less than 19 mm,
C5,600 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is not less than 19 mm and not greater than 22 mm,
C7,000 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter

Columns reconstructed from the extracted text; check against the Gazette page.

Show original extracted text (diagnostic, not authoritative)
P       Maximum allowable working pressure in tons/sq.in,

D       is the diameter of bolt or stud over threads in inches,

N       is the number of bolts or studs securing the part,

n       is the number of threads of screws per inch,

C       4,700 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter

        over thread is less than 19 mm,

C       5,100 for steel bolts or studs of 30 tons/sq. in. minimum ultimate tensile stress where the diameter

        over thread is less than 19 mm,

C       5,600 for steel bolts or studs of 35 tons/sq. in. minimum ultimate tensile stress where the diameter

        over thread is not less than 19 mm,

C       5,600 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter

        over thread is not less than 19 mm and not greater than 22 mm,

C       7,000 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter

over thread is greater than 22 mm.

‘A’ is the area in square inches of the surface supported by the bolts or studs. For jointed flanges the area shall be taken to extend to mid-way between the pitch lines of the bolts and the inner edge of the flange by which the part is secured.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Bolts and studs connecting vessel parts such as shells, end plates and tube plates must be steel. Their maximum working pressure is found from Equation (16/1).

Key points

  • (1) Bolts and studs connecting parts of the vessel must be made of steel.
  • (2) Equation (16/1) gives P, the maximum allowable working pressure in tons/sq.in. Its symbols are:
  • D: diameter of the bolt or stud over threads, in inches;
  • N: number of bolts or studs securing the part;
  • n: number of threads per inch;
  • C: a constant that depends on the minimum ultimate tensile stress of the steel and on the diameter over thread (whether it is less than 19 mm, between 19 mm and 22 mm, or greater than 22 mm);
  • A: area in square inches of the surface supported by the bolts or studs.
  • For jointed flanges, area A extends to mid-way between the bolt pitch lines and the inner edge of the flange securing the part.

Watch out

  • The equation and the table of C values do not come through cleanly in the extracted text. Use the Official text tab and the Gazette page for the exact equation and C values.
  • The equation mixes inch units with mm diameter limits for C. Use the units exactly as the text gives them.

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

Historical 1950-edition reg.Heading as OCR'dHeading similaritySource image
208Bolts and Studs100%Chapter IV (DPIIT scan), image 8
511Joint bolts and studs for Cast Iron Economisers100%Chapter XI (DPIIT scan), image 4
572Raised manhole frames, cover plates and joint bolts75%Chapter XII (DPIIT scan), image 5
IBR 1950 regulation 208 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 208 page for its amendments.

Reg. 208
STAYS

Bolts and Studs

a) Bolts and studs connecting parts by boilers such as shell, end plates, tube plates, furnaces, up takes, externally fitted manhole covers, mountings, etc. may be made either of steel or good quality wrought iron.
b) The maximum working pressure for the bolts or studs shall be calculated by the following formula: -
W. P. =

N x C

( D - 1.28 )2 Eqn.(45)
A n

where
D is the diameter of bolt or stud over threads in inches

N is the number of bolts or studs securing the part,

n is the number of threads of screws per inch,

C = 4,700 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch,

C = 5,100 for steel bolts or studs of 30 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch

C = 5,600 for steel bolts or studs of 35 tons/sq. in minimum ultimate tensile stress where the diameter over thread is less than 3/4 inch.

C = 5,600 for steel bolts or studs of 28 tons/sq. in minimum ultimate tensile stress where the diameter over thread is not less than 3/4 inch and not greater than 7/8 inch.

C = 7,000 for steel bolts for studs of 28 tons/sq. in minimum ultimate tensile stress where the diameter over thread is greater than 7/8 inch.

When the material is iron, a reduction, of 15 per cent shall be made in the working pressure as calculated by the formula.

A is the area in square inches of the surface supported by the bolts or studs. For jointed flanges the area shall be taken to extend to midway between the pitch line of the bolts and the inner edge of the flange by which the part is secured.
IBR 1950 regulation 511 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 511 page for its amendments.


Reg. 509, Reg. 510, Reg. 511
STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMISER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

CAST IRON, TUBES AND HEADERS

Standard test piece

The tensile test bar shall conform to the dimensions shown in the following drawing. Bars may be tested with either plain or screwed ends.

B D A P R C E F Lp Ls

In.
1.20

In.
0.798
Sq.in.
0.50
In.
2
In.
3-1/2
In.
2
In.
1-1/8
SF
1-1/8
SW
In
1-1/8
In.
8-1/4
In.
5-7/8

The test bars shall be cast as cylindrical bars of the diameters given in Col. B and machined to the dimensions given in Cols. D & P in the above Table.

See Figure



Reg. 510
STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMIZER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

CONSTRUCTIONAL REQUIREMENTS

Cast Iron Economisers

The manufacturer shall, on the basis of design details, satisfy the Inspecting Authority regarding the design and the strength of all parts of cast iron economisers subject to the following maximum working pressure:-

Max. W.P.
(1) Ordinary Vertical Tube 325 lbs. /sq. in.
(2) Ordinary Vertical Tube with strengthened tubes 375 lbs. /sq.in.
(3) Ring Stay Vertical Tube 475 lbs./sq. in.
(4) Gilled Tube type approved design 45.7 kg/cm² (650 lbs./sq.in.)

Reg. 511
STANDARD CONDITIONS FOR THE DESIGN AND CONSTGRUCTION OF ECONOMIZER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS

CONSTRUCTIONAL REQUIREMENTS

Joint bolts and studs for Cast Iron Economisers
a) The maximum working pressure for the bolts and studs shall be calculated by Regulation 518.
b) The use of studs tapped into cast iron is permissible where:-

(i) The studs and nuts are not in the path of the flue gases.
(ii) The studs are carefully threaded to gauge and fitted into tapped holes of ample depth.

For economiser of Gilled Tube type of approved design made from 16.5 grade iron the limitation for a maximum working pressure may be increased to 52.7 kg/cm² (750 lbs./sq.in.)
IBR 1950 regulation 572 as last published in the DPIIT web edition (archived 2022)

Unofficial archived copy, not verified; see the regulation 572 page for its amendments.

Reg. 572, Reg. 573, Reg. 574

Raised manhole frames, cover plates and joint bolts

Raised circular manhole frames not exceeding 16 inches in diameter shall not be less than ¾ inch thick in all parts.

The circular cover plates and joint flanges for such frames shall be not less than-

1 inch thick for pressures not exceeding 120 pounds per square inch.

1- 1/8 inches thick for pressures exceeding 120 pounds per square inch but not exceeding 200 pounds per square inch.

1 ¼ inches thick for pressure exceeding 200 pounds but not exceeding 250 pounds per square inch.

For pressure exceeding 250 pounds per square inch, raised circular manhole frames shall not be fitted.

The cover plates shall be secured by at least sixteen steel bolts not less than 1 inch diameter, such that the stress in the bolts due to steam pressure shall not exceed:-
5,000 pounds per square inch for 1 inch bolts.
6,000 pounds per square inch for 1- 1/8 inches bolts.
6,500 pounds per square inch for 1 ¼ inches bolts.

For the purpose of calculation the pressure shall be assumed to act on the whole area within the pitch circle of the bolts and the bolt area at the bottom of the screw thread shall be taken.



Reg. 573

Stand Pipes and branches-
a) The thickness and bolting of all flanges for joining the mountings  and fittings shall be in accordance with the dimensions as laid down in Appendix- E to these regulations. In no case, however, shall the thickness of flanges be less than 13 mm.
b)
(i) The Wall thickness of nozzles and other connections shall not be less than that specified for the applicable loading, namely, internal pressure, bending and static loads.
(ii) The pressure loading shall be determined by regulation 564, but in no case shall the thickness be less than that calculated by the following formula:-

t = 0.04D + 2.5 mm (equation XII/10)

where, t is the thickness of standpipe and D is the outside diameter of connection. If the branch is connected by screwing, the thickness ‘t’ shall be measured at the root of the thread.
c) Where a double flanged steam pipe is tapered, the thickness of flange joining the boiler and fitting shall correspond to the bore of pipe at the flange connection in accordance with Appendix-E to these regulations.


Reg. 574

Stayed Flat surfaces (other than Crowns of Vertical Boilers).

Stayed heads/ Braced and stayed surfaces.

For various braced and stayed flat plates and those which by these regulations require staying as flat surfaces with braces or stay bolts of uniform diameter symmetrically spaced, the thickness should be calculate by the following formula; namely:-

                                             __________
                        e  =  Cd      Ö P        +   e1
Ö   f1

Where,

P=design pressure in kgf/cm²
e=thickness, in mm.
d=diameter of the largest circle taken between staying points of the plate (in mm)
f1=0.85 f (f as defined in regulation 271), kfg/cm²
e1=additional thickness equal to 0.75 mm (0.03 in)
C=coefficient having the following values:-

1) C=0.33 for flanged connections;

NOTE:
d is the diameter of the largest circle taken from the commencement of the curvature of the flange.
2) C=0.40 for stays screwed in plate with nut or screwed and welded, or plain end strength welded on the outside;
3) C=0.33 for screwed bar stays with washer of not less than 3.5 times the diameter of bar stay;
4) C=0.31 for screwed bar stays with reinforcing plate, washer and nut on the outside.

NOTES:
1. If the plate is stayed in any other way, average values of C shall be taken into account.

2. If the plate is flame swept, the thickness shall be increased by 10%.

3. The welding materials used in the manufacture of these plates shall not have the ultimate tensile strength less than that of the plate used.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
862
PDF page index
862 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash 7ecde2eec3225a42
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 571, Regulation 571, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.862. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.