571. Bolts and Studs .─(1) Bolts and studs connecting the parts of the vessel such as shell, end plates , tube plates shall be made of steel.
(2)The maximum working pressure for the bolts and studs shall be as per by the following Equation,─
N x C 1.28 2
P = -------- D - ----- Equation (16/1)
A n
Where,
| P | Maximum allowable working pressure in tons/sq.in, |
| D | is the diameter of bolt or stud over threads in inches, |
| N | is the number of bolts or studs securing the part, |
| n | is the number of threads of screws per inch, |
| C | 4,700 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less than 19 mm, |
| C | 5,100 for steel bolts or studs of 30 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is less than 19 mm, |
| C | 5,600 for steel bolts or studs of 35 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is not less than 19 mm, |
| C | 5,600 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter over thread is not less than 19 mm and not greater than 22 mm, |
| C | 7,000 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter |
Columns reconstructed from the extracted text; check against the Gazette page.
Show original extracted text (diagnostic, not authoritative)
P Maximum allowable working pressure in tons/sq.in,
D is the diameter of bolt or stud over threads in inches,
N is the number of bolts or studs securing the part,
n is the number of threads of screws per inch,
C 4,700 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is less than 19 mm,
C 5,100 for steel bolts or studs of 30 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is less than 19 mm,
C 5,600 for steel bolts or studs of 35 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is not less than 19 mm,
C 5,600 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameter
over thread is not less than 19 mm and not greater than 22 mm,
C 7,000 for steel bolts or studs of 28 tons/sq. in. minimum ultimate tensile stress where the diameterover thread is greater than 22 mm.
‘A’ is the area in square inches of the surface supported by the bolts or studs. For jointed flanges the area shall be taken to extend to mid-way between the pitch lines of the bolts and the inner edge of the flange by which the part is secured.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Bolts and studs connecting vessel parts such as shells, end plates and tube plates must be steel. Their maximum working pressure is found from Equation (16/1).
Key points
- (1) Bolts and studs connecting parts of the vessel must be made of steel.
- (2) Equation (16/1) gives P, the maximum allowable working pressure in tons/sq.in. Its symbols are:
- D: diameter of the bolt or stud over threads, in inches;
- N: number of bolts or studs securing the part;
- n: number of threads per inch;
- C: a constant that depends on the minimum ultimate tensile stress of the steel and on the diameter over thread (whether it is less than 19 mm, between 19 mm and 22 mm, or greater than 22 mm);
- A: area in square inches of the surface supported by the bolts or studs.
- For jointed flanges, area A extends to mid-way between the bolt pitch lines and the inner edge of the flange securing the part.
Watch out
- The equation and the table of C values do not come through cleanly in the extracted text. Use the Official text tab and the Gazette page for the exact equation and C values.
- The equation mixes inch units with mm diameter limits for C. Use the units exactly as the text gives them.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 208 | Bolts and Studs | 100% | Chapter IV (DPIIT scan), image 8 |
| 511 | Joint bolts and studs for Cast Iron Economisers | 100% | Chapter XI (DPIIT scan), image 4 |
| 572 | Raised manhole frames, cover plates and joint bolts | 75% | Chapter XII (DPIIT scan), image 5 |
IBR 1950 regulation 208 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 208 page for its amendments.
| Reg. 208 STAYS Bolts and Studs
|
IBR 1950 regulation 511 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 511 page for its amendments.
|
CAST IRON, TUBES AND HEADERS | |||||||||||||||||||||
| |||||||||||||||||||||
|
CONSTRUCTIONAL REQUIREMENTS | |||||||||||||||||||||
| |||||||||||||||||||||
| Reg. 511 CONSTRUCTIONAL REQUIREMENTS | |||||||||||||||||||||
|
IBR 1950 regulation 572 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 572 page for its amendments.
| Reg. 572, Reg. 573, Reg. 574 | |||||||||||||||||||||||||
Reg. 573 Stand Pipes and branches-
Reg. 574 Stayed Flat surfaces (other than Crowns of Vertical Boilers). Stayed heads/ Braced and stayed surfaces.
| |||||||||||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 571, Regulation 571, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.862. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.