584. Tube thinning calculations.─ (1) Tube thinning calculations shall be using the equation given below, based on the measured values.

(2)The thinning shall be within 5% to 8%.

        (T-t) - (D - d)

% Thinning = ----------------- x 100  Equation (16/2)

        2 x Tube thickness

Where,

T = Internal diameter of the tube after expansion t = Internal diameter of the tube before expansion

D = Tube sheet Hole Diameter d = Tube outer diameter.

Parts of this extracted text look garbled; read the Gazette page before using any value.

Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.

Independent explanation — not the law · draft · engineer review in progress

In short

Tube thinning from expansion is calculated with Equation (16/2) using measured values, and must fall within 5% to 8%.

Key points

  • (1) Thinning is calculated from measured values using Equation (16/2). The equation compares the change in tube internal diameter with the clearance between the tube and the tube sheet hole, relative to the tube thickness.
  • Symbols:
  • T: internal diameter of the tube after expansion;
  • t: internal diameter of the tube before expansion;
  • D: tube sheet hole diameter;
  • d: tube outer diameter.
  • (2) The thinning must be within 5% to 8%.

Watch out

  • The equation layout is broken in the extracted text. Check the Gazette page for the exact form of Equation (16/2).

Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.

Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).

Orientation hints (unverified)

These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.

No candidate heading found in the historical print edition.

Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Instrument
Indian Boiler Regulations, 2026 (made by the Central Boilers Board under s.40 of the Boilers Act, 2025)
Notification
F.No. P-30014/3/2021-Boiler dated 7 Aug 2026
Published
Gazette of India, Extraordinary, Part III Sec. 4, No. 596, 1 Oct 2026 (CG-DL-E-06102026-276813)
In force
1 Oct 2026 (reg. 1(3): date of publication in the Official Gazette)
Printed Gazette page
864–865
PDF page index
864–865 · open official e-Gazette PDF
Extraction
pdftotext layout mode, sequential regulation detector · text hash eaa4a52ce54441bc
Verification
Official text — not yet verified
Amendments checked
None known after 1 Oct 2026 as of build date (not a guarantee). Amendment log
How to cite

Indian Boiler Regulations, 2026, reg. 584, Regulation 584, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.864–865. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).

The citation refers to the government publication. Cite the Gazette, not this website.

Help improve this page

Engineers like you keep IBRsource accurate. Every checked correction or tip helps the next reader.