Indian Boiler Regulations, 2026 · Chapter 13 · Qualification Tests for Welders and Welding Operators
Regulation 527. Tests for requalification of a welder / welding operator
Not yet checked against the official Gazette; verify before relying on it.
527. Tests for requalification of a welder / welding operator.─ (1)The material of plates, tubes, pipes and electrodes used for practical tests shall conform to the requirements of appropriate regulations as may be applicable in each case.
(2)For requalification, the welder or welding operator need not be examined in theoretical subjects. He shall be required to qualify in the following practical tests, namely: -
(i)Plate Welding; a groove welded joint shall be made in a position originally qualified.
(ii)Pipe and Tube welding; as mentioned in regulation 525.
(iii)Cladding; as mentioned in regulation 526.
(3)When a welder is continuously engaged on production weld, test on the actual production joints to the satisfaction of the Competent Authority may be accepted as an alternative to the tests prescribed as above under clauses (i), (ii) and (iii) of sub-regulation (2).
In short
Regulation 527 sets the tests for requalifying a welder or welding operator. There is no theory examination, only practical tests.
Key points
- (1) Plates, tubes, pipes and electrodes must meet the regulations that apply to them.
- (2) The practical tests are:
- (i) plate welding: a groove welded joint in a position originally qualified;
- (ii) pipe and tube welding, as in regulation 525;
- (iii) cladding, as in regulation 526.
- (3) If the welder is continuously engaged on production welds, a test on actual production joints may be accepted instead, if the Competent Authority is satisfied.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 8 | Welding | 100% | Chapter I (DPIIT scan), image 3 |
| 610 | Tests for Requalification | 100% | Chapter XIII (DPIIT scan), image 3 |
Amendment history of the candidate IBR 1950 regulations: Reg. 8 (2 amendments)
IBR 1950 regulation 8 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 8 page for its amendments.
| Reg. 8 Welding:- |
| (a) The use of welding in the construction of boilers shall be permitted only where specifically provided for in the standard conditions. |
IBR 1950 regulation 610 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 610 page for its amendments.
| Reg. 610, Reg. 611 A, Reg. 611 B Reg 610 Tests for Requalification | |||||||||||||||||||||||||||||||||||||||||||
Reg. 611 Examination of test specimens for initial qualification tests:- (a) Groove welded plate specimens
(b) Fillet welded plate specimens.-
| |||||||||||||||||||||||||||||||||||||||||||
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.


Indian Boiler Regulations, 2026, reg. 527, Regulation 527, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.846–847. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.