Indian Boiler Regulations, 2026 · Chapter 13 · Qualification Tests for Welders and Welding Operators
Regulation 526. Cladding
Not yet checked against the official Gazette; verify before relying on it.
526. Cladding.─(1) This test is required only for welders or welding operators doing corrosion resistant/hard facing overlay.
(2)The qualification test coupon shall be of minimum size of 150 mm × 150 mm x T (thickness of base metal).
(3)The weld overlay cladding shall be of 38 mm wide (minimum) and 5 mm thick (minimum two layers).
(4)The weld overlay shall consist of a minimum of three weld beads in the first layer. (See Table 13/9 of chapter 13 for qualification limits.)
Note - Every welded test piece for the examination of welders shall be stamped with an identification mark on either side of the weld.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
The cladding test is needed only for welders or welding operators who do corrosion-resistant or hard-facing weld overlay.
Key points
- (2) The test coupon must be at least 150 mm × 150 mm × T, where T is the base metal thickness.
- (3) The overlay must be at least 38 mm wide and 5 mm thick, in at least two layers.
- (4) The first layer must have at least three weld beads. Qualification limits are in Table 13/9.
Watch out
- Every welded test piece for welder examination must be stamped with an identification mark on either side of the weld.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.

Indian Boiler Regulations, 2026, reg. 526, Regulation 526, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.846. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.