Regulation 56 — Hydraulic Test

Unofficial DPIIT web edition · not verified3 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 56
MATERIALS OF CONSTRUCTION

SEAMLESS FERRITIC PIPES FOR HIGH TEMPERATURE SERVICE

 Hydraulic Test

(i) Each pipe shall be tested by the manufacturer and shall withstand a hydraulic pressure to one and half times the design pressure but not greater than pressure calculated by the following formula given below.  In the absence of working pressure is indicated in the Test Certificate then the tested pressure indicated in the Test Certificate divided by 1.5 shall be the maximum working pressure 

P = 2 S t / d                          

where     P = test pressure

                D = specified outside diameter of the pipe

                t = specified wall thickness of the pipe

S = stress which shall be taken as 40% of the minimum tensile strength at room temperature.

(ii)  Notwithstanding anything contained in the above clause, the hydraulic test at the maker's works may be dispensed with provided that the pipes are subject to non destructive testing by an appropriate method like Ultrasonic or Eddy current or stray flux testing

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

SEAMLESS CHROMIUM-MOLYBDENUM STEEL BOILER AND SUPER HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 538 DEGREE C (1,000 DEGREE F).

Hydraulic Test

Each tube shall be tested at the maker’s works on completion of manufacture and shall withstand a hydraulic pressure, to one and a half times the design pressure subject to a minimum of 0.70 kgf/mm2 but not greater than pressure calculated by the following formula:

                       2 St
                       P = ----------
                       D
Where, P = test pressure
       D = outside diameter of the tube
       t = nominal wall thickness of the tube
       S = stress which shall be taken as 40% of the minimum tensile
       strength at room temperature.

(ii)Notwithstanding anything contained in clause (i), the hydraulic test for tubes in Makers’ premises may be dispensed with by the Inspecting Authority provided that the tubes are subject to non-destructive testing by an appropriate method like ultrasonic or/and Eddy current testing.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
1994-02-07G.S.R. 107 OCR of scan(i)SubstitutedReplaces the tube hydraulic test: 1.5 times design pressure, minimum 0.70 kgf/mm2, capped at P=2ST/D with S at 40% of minimum tensile strength.
Uncertain: Units 'kgf/mm5' as OCR'd.
listed before the capture
2001-04-10G.S.R. 219SubstitutedReplaced as part of the block substitution of regulations 36 to 56 (tube specifications).listed before the capture
2008-06-27G.S.R. 123 OCR of scan(i)OmittedOmits the sentence deriving working pressure from test pressure divided by 1.5.listed before the capture

Possible IBR 2026 successors (heading match, unverified): Reg. 167, Reg. 215, Reg. 296, Reg. 297, Reg. 298, Reg. 345, Reg. 352, Reg. 361, Reg. 383, Reg. 503