Pads Welded to shell or the attachment of Flanged Mountings
(see Fig XII/90) -The size of outer peripheral fillet welds by which circular pads are attached to shell plates shall be determined by the following formula XII/36, but shall in no case be less than the inner welds or nor less than the minimum specified for plate thickness in Table XII/3:-
2A-D1 L1
Lo = Equation XII/36
Do
Where,
Lo is size of fillet weld around outer periphery of pad, in inches.
L1 is size of fillet weld around inner periphery of pad, in inches.
A is cross sectional area of opening in shell (based on minimum thickness In square inches see Regulation 571.
Do is outer diameter of pad, in inches
D1 is inner diameter of pad, in inches.