The working pressure for uptake tubes of vertical boilers shall be determined by the following formula:-
(i)When an internal liner is not fitted:-
100 (t-2)
W.P. = Equation XII/33.
D
(ii)When an internal liner is fitted extending below the low water level:-
725 (t-1)²
W.P. = x Equation XII/34.
D (L+24)
Where,
W.P. is working pressure in pounds per square inch. t is thickness of the uptake in thirty seconds of an inch.
D is external diameter in inches.
L is length of the uptake in inches, measured between the circumferential seams.
In no case shall the thickness of an uptake tube be less than 3/8 inch.