Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 599 — Cross Tubes
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 598, 600, 601. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 598, Reg. 599, Reg. 600, Reg. 601 | ||||||||||||||||||||||||||||||||||||||||||||||
Reg. 599 Cross Tubes
Reg. 600 Pads Welded to shell or the attachment of Flanged Mountings
Reg. 601
| ||||||||||||||||||||||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Cross Tubes
Internal diameter of cross tubes shall not exceed 12 inches. The working pressure of the tubes shall be determined by the following formula:-
200(t-7)
W.P. = Equation XII/35.
D
t is thickness in thirty seconds of an inch of the cross tube.
D is internal diameter in inches of the cross tube.
In no case shall be thickness of a cross tube be less than 5/16 inch