248. Cylindrical Headers.─ (1) Where cylindrical headers are provided, their maximum allowable working pressure shall be determined by Equation (6/1).
(2)The attachment of ends and the method of calculating the maximum allowable working pressure shall be in accordance with clause (b) of sub-regulation (6) of regulation 246, subject to the following modifications:-
K = 0.19 for ends integral with or flanged and butt welded to the header. = 0.28 for ends directly strength welded to the header in an approved manner, and d = internal diameter of the header.
The required thickness shall be determined by the following formula:
t= d x√P x K + C Equation (6/8)
f
Where,
P = maximum allowable working pressure in kg/cm2 (g), f = maximum permissible stress values as available in the governing codes of the Country of the material to which it belongs (kg/cm2), t = thickness of the plate at the weakest part in mm,
C = 1 mm,
K = 0.19 for ends integral with or flanged and butt welded to the header.
= 0.28 for ends directly strength welded to the header in an approved manner, d = internal diameter of the header.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Cylindrical headers are calculated using the tube formula, with a modified method for their ends.
Key points
- (1) Maximum allowable working pressure of cylindrical headers is found by Equation (6/1) of regulation 244.
- (2) Ends are attached and calculated as in clause (b) of sub-regulation (6) of regulation 246, with these changes:
- K = 0.19 for ends integral with, or flanged and butt welded to, the header;
- K = 0.28 for ends directly strength welded to the header in an approved manner;
- d = internal diameter of the header.
- Required end thickness is given by Equation (6/8), using d, P, K, the permissible stress f and C = 1 mm.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
No candidate heading found in the historical print edition.
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 248, Regulation 248, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.646–648. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.