246. Rectangular Headers symmetrical in form.─ (1) The maximum allowable working pressure shall not exceed the smaller of the value obtained from the following formula:
(a) cf(t – C1)2
P = ------------------- Equation (6/3)
Equation (6/4)
b2
(b) 6.25t2.f.E
P = ------------
w2
Where, P = maximum allowable working pressure,
t = thickness,
b = internal breadth between the supporting sides of the header,
c = 3.413 for wrought steel and 2.926 for steel castings,
Where the sides are corrugated or otherwise reinforced by substantial
f = supports so that the length of the portion between the corrugations or supports
does not exceed b, shall be taken as 5.82 for wrought steel and 5.12 for steel
c1 = castings,
w = permissible stress at working metal temperature as given in the table 6/3 under
E = sub-regulation (3),
0.08 cm,
internal width of the header between the tube plate and the Opposite side, efficiency of ligaments between the holes.
(2)If the faces of the headers are machined locally at the tube holes or hand holes, the thickness at the part may be as much as 4.8 mm less than given by the above equation; but irrespective of the thickness obtained by the use of the formulae, the thickness of the headers at the tube holes shall not be less than:-
t = √(̅̅C̅ x̅̅ d̅ +̅̅̅ C1) Equation (6/5)
where, t = thickness,
d = diameter of the hole,
C = 0.2235 mm,
C1 = 6.4 mm.
In no case shall the thickness be less than 8 mm except that in small patches not exceeding 322 mm2 in area, the thickness may be 50 percent of the thickness used in the Equations (6/3) and (6/4)
(3)The permissible stress at working metal temperature shall be as given in the table below:-
Table 6/3: Permissible Stress at Working Temperature for Rectangular Section Headers
| Serial No. | Working Metal Temperature in degrees | Cast steel 44- 45 kg/mm2 | Carbon and Alloy Steels |
|---|---|---|---|
| C | kg/cm2 (g) | The lower value obtained in each case at the specified temperature calculated on the following basis: | |
| (1) | (2) | (3) | (4) |
| 1. | 288 | 703 | For temperatures at or below 454°C T.S Et ----- or ---- 2.7 1.5 For temperatures above 454°C Sr --- or Sc 1.6 |
| 2. | 316 | 633 | |
| 3. | 343 | 562 | |
| 4. | 371 | 532 | |
| 5. | 399 | 505 | |
| 6. | 427 | 475 | |
| 7. | 454 | 443 | |
| 8. | 482 | 309 |
Table structure read from the Gazette PDF, page 645. Verification status as for the text above.
Show original extracted text (diagnostic, not authoritative)
Serial No. Working Metal Cast steel 44- Carbon and Alloy Steels
Temperature in 45 kg/mm2
The lower value obtained in each case at the
degrees kg/cm2 (g) specified temperature calculated on the following
C basis:
(1) (2) (3) (4)
1. 288 703 For temperatures at or below 454°C
2. 316 633
3. 343 562 T.S Et
4. 371 532 ----- or ----
5. 399 505 2.7 1.5
6. 427 475 For temperatures above 454°C
7. 454 443 Sr
8. 482 309 --- or Sc
1.6Where, Ts = minimum tensile strength of the material at room temperature,
Et = yield point (0.2% proof stress) at the working metal temperature ‘t’, Sr = the average stress at the temperature ‘t’ to produce rupture in 100,000 hours and in no case more than 1.33 times the lowest stress to produce the rupture in 100,000 hours,
Sc = the average stress at the temperature ‘t’ to produce an elongation of 1% (creep) in 100,000 hours.
(4)The working metal temperature shall be taken as follows:
(a)For saturated steam and water drums and headers, the saturation temperature corresponding to the working pressure of the boiler plus 28°C.
(b)For superheater headers, the designed maximum steam temperature for the header plus 28°C.
(5)(a) Where headers are adequately protected from the gases of combustion or swept by such gases in the third or subsequent pass of a boiler, the working metal temperature shall be taken as the saturation or designed maximum steam temperature as defined above, whichever applies.
(b)A covering or refractory or insulating material which may be liable to become dislodged shall not be deemed adequate protection.
(6)(a)The ends of rectangular headers may be formed integral with the header or attached by welding.
(b)The maximum allowable working pressure for the flat ends shall be calculated by the following formula: -
f (t – C)2 Equation (6/6)
P = -----------------
d2K
where, P = Maximum allowable working pressure in kg/cm2 (g), f = maximum permissible stress values as available in the governing codes of the country of the material to which it belongs (kg/cm2), t = thickness of the plate at the weakest part in mm, d = the least width between the walls of the rectangular header in mm,
C = 1 mm,
K = 0.32 for ends integral with or flanged and butt welded to the header,
= 0.40 for ends directly strength welded to the header in an approved manner.
Parts of this extracted text look garbled; read the Gazette page before using any value.
Tables and formulae are shown in their extracted layout. Alignment, superscripts and subscripts may be lost. The Gazette page image is authoritative.
In short
Regulation 246 covers rectangular headers that are symmetrical in form: how to find their maximum allowable working pressure, minimum thickness at tube holes, permissible stress, working metal temperature and flat end design.
Key points
- (1) The working pressure is the smaller of the values from Equation (6/3) and Equation (6/4). They use thickness t, internal breadth b, internal width w, ligament efficiency E, permissible stress f and constants c and C1. The constant c depends on whether the material is wrought steel or steel castings and on whether the sides are corrugated or reinforced. The symbol list is misaligned in the extracted text; check the Gazette page for the exact values.
- (2) Where faces are machined locally at tube holes or hand holes, thickness there may be up to 4.8 mm less than the equation gives. Thickness at tube holes must still not be less than Equation (6/5), with C = 0.2235 mm and C1 = 6.4 mm.
- (3) Permissible stress comes from Table 6/3: listed values for cast steel by temperature, and for carbon and alloy steels the lower of T.S./2.7 or Et/1.5 at or below 454°C, and Sr/1.6 or Sc above 454°C.
- (4) Working metal temperature: drums and headers for saturated steam and water, saturation temperature plus 28°C; superheater headers, designed maximum steam temperature plus 28°C.
- (5)(a) Headers adequately protected from combustion gases, or swept by gases in the third or later pass, take the saturation or design steam temperature without the addition.
- (6) Ends may be integral or welded on. Flat ends use Equation (6/6) with C = 1 mm and K = 0.32 (integral, or flanged and butt welded) or 0.40 (directly strength welded in an approved manner).
Watch out
- Thickness must never be less than 8 mm, except small patches not exceeding 322 mm2, which may be 50 percent of the equation thickness.
- (5)(b) Refractory or insulating covering that may become dislodged does not count as adequate protection.
Written by IBRsource editors · last edited 2026-11-20. Explanations simplify and are not a design method, testing procedure or authorisation. Requirements come from the complete regulations, the Gazette and approved documentation.
Comparison pending: the IBR 1950 text in force on 30 September 2026 is not yet established for this provision, so no change is claimed (how this works).
Orientation hints (unverified)
These candidates come from automated heading matching against DPIIT's scanned historical print edition of IBR 1950. That edition uses imperial units and riveted-construction provisions, so it is not the operative 2026 predecessor text. Regulation numbers alone never prove equivalence.
| Historical 1950-edition reg. | Heading as OCR'd | Heading similarity | Source image |
|---|---|---|---|
| 341 | Headers Irregular in Form | 75% | Chapter VII (DPIIT scan), image 3 |
IBR 1950 regulation 341 as last published in the DPIIT web edition (archived 2022)
Unofficial archived copy, not verified; see the regulation 341 page for its amendments.
| Reg. 341 Headers Irregular in Form
|
Images of the official Gazette pages that contain this regulation. Click to zoom. Compare word by word before relying on the extracted text.



Indian Boiler Regulations, 2026, reg. 246, Regulation 246, Gazette of India, Extraordinary, Part III—Section 4, No. 596, 1 October 2026, printed p.644–646. https://egazette.gov.in/WriteReadData/2026/276813.pdf (text consulted via IBRsource, 2026-11-23).
The citation refers to the government publication. Cite the Gazette, not this website.