BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 341 — Headers Irregular in Form

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 341

Headers Irregular in Form

a) In cases where the headers are of such irregular form as to render impracticable the application of a formula for the determination of thickness, the manufacturer shall show the suitability of the headers for the working conditions by indicating practically the maximum internal hydraulic pressure which a header, made to the same design and of similar material, will withstand without permanent deformation. The maximum working pressure for similar headers may then be determined by the following formulae:-

W. P. = P1 x Permissible stress at working metal temperature Eqn.(90)

F x C

 

where,

W. P. = The working pressure in lbs. Per sq. In.
P1 = The maximum internal hydraulic pressure withstood without, permanent deformation.
F = 1.75 for wrought steel and 2 for cast steel.
C = 15500 for wrought steel of 24 tons per sq. in minimum ultimate tensile stress.
= 16500 for wrought steel of 26 tons per sq. in minimum ultimate tensile stress.
= 18000 for wrought steel of 28 tons per sq. in minimum ultimate tensile stress.
= 21000 for wrought steel of 32 tons per sq. in minimum ultimate tensile stress.
= 22000 for wrought steel of 34 tons per sq. in minimum ultimate tensile stress.
= 15500 for wrought steel of 28 tons per sq. in minimum ultimate tensile stress.

Earlier text: the 2008 DIPP web edition

Headers Irregular in Form

a)In cases where the headers are of such irregular form as to render impracticable the application of a formula for the determination of thickness, the manufacturer shall show the suitability of the headers for the working conditions by indicating practically the maximum internal hydraulic pressure which a header, made to the same design and of similar material, will withstand without permanent deformation. The maximum working pressure for similar headers may then be determined by the following formulae:-

                   Permissible stress at working metal
W. P. = P1 x                 temperature            Eqn.(90)
                                F x C

where,

W. P. = The working pressure in lbs. Per sq. In.

P1 = The maximum internal hydraulic pressure withstood without, permanent deformation.

F = 1.75 for wrought steel and 2 for cast steel.

C = 15500 for wrought steel of 24 tons per sq. in minimum ultimate tensile stress. = 16500 for wrought steel of 26 tons per sq. in minimum ultimate tensile stress. = 18000 for wrought steel of 28 tons per sq. in minimum ultimate tensile stress. = 21000 for wrought steel of 32 tons per sq. in minimum ultimate tensile stress. = 22000 for wrought steel of 34 tons per sq. in minimum ultimate tensile stress. = 15500 for wrought steel of 28 tons per sq. in minimum ultimate tensile stress.

Possible IBR 2026 successors (heading match, unverified): Reg. 246, Reg. 247