Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 586 — Fire-box Crown stays for Loco-type Boilers
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 585A, 585B. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 585 a, Reg. 585 b, Reg. 586 | |||||||||||||||||
Reg. 585 b Circumferential stays for circular furnaces and fire-boxes
Reg. 586 Fire-box Crown stays for Loco-type Boilers
| |||||||||||||||||
Earlier text: the 2008 DIPP web edition
Fire-box Crown stays for Loco-type Boilers
Where fire-box crown stays are directly attached to a semi-cylindrical outer casing, and the fire-box top is cambered and fitted with stays arranged as shown in Figure XII/78, the thickness of the outer casing shall be sufficient to provide not less than three engaging threads, of which not less than one shall be full thread in stays not normal to the stayed surface, but if the thickness of the plate is not sufficient to give one engaging full thread the plate shall be reinforced.
Where vertical stays only are used to take part of the load on the fire-box top, boilers
with shells 4 feet and 6 inches diameter and over shall be fitted with transverse stay (see Figure XII/79). Stays may be attached as shown in Figures XII/39, XII/40 and XII/41.
Possible IBR 2026 successors (heading match, unverified): Reg. 475, Reg. 477, Reg. 478