Regulation 585B — Circumferential stays for circular furnaces and fire-boxes
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 586, 585A. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 585 a, Reg. 585 b, Reg. 586 | |||||||||||||||||
Reg. 585 b Circumferential stays for circular furnaces and fire-boxes
Reg. 586 Fire-box Crown stays for Loco-type Boilers
| |||||||||||||||||
Earlier text: the 2008 DIPP web edition
Circumferential stays for circular furnaces and fire-boxes
The diameter of the stay shall be not less than ¾ inch or twice the thickness of the firebox plate, whichever is the greater. In the case of screwed threads the diameter shall be measured over the threads.
The pitch of the stays at the fire-box shall not exceed 14 times the thickness of the firebox plate.