BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 347 — Reg. 347 B

1 amendment found

Text in the 2008 DIPP web edition

Printed as separate lettered regulations:

Unofficial DIPP web edition (2008) · machine-extracted · not checked against the Gazette

Regulation 347A — Reg. 347 B

Regulation 347B — Cold bend test (for pipes over 102 mm. (4in.) Nominal bore)

Regulation 347C — Reg. 347 D, Reg. 347 E

Regulation 347D — Additional test

Regulation 347E — Tensile test

Regulation 347F

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)
1994-10-31G.S.R. 562 OCR of scanTable ISubstitutedChanges the sulphur and phosphorus maximum per cent entry "0.06" to "0.05".
Uncertain: OCR reads old entry as '0Q6'; read as 0.06.