Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 347B — Cold bend test (for pipes over 102 mm. (4in.) Nominal bore)
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 347A. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 347 A Reg. 347 B
|
Earlier text: the 2008 DIPP web edition
Cold bend test (for pipes over 102 mm. (4in.) Nominal bore)
strip not less than 38 mm. (1-1/2 in.) wide cut circumferentially from one end of each selected pipe shall when cold withstand, without showing either crack or flaw being doubled over in the direction of original curvature round a bar, the diameter of the bar being:-
For pipes up to and including 10mm (3/8 3 times the
in.) thick thickness
4 times the
For pipes over 10mm. thick
thickness