BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 347A — Reg. 347 B

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulation 347B. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette

Reg. 347 A Reg. 347 B

Flattening test (for pipes up to and including 102 mm. (4 in.) Nominal bore)

As per requirements of Chapter II.

(i) For cold drawn seamless construction-Regulation 39.
(ii) For hot finished seamless construction-Regulation 44(b).
(iii) For molybdenum seamless construction-Regulation 49 (b).
(iv) For Chrome molybdenum seamless construction-Regulation 54(b).
(v) For electric resistance welded tubes-Regulation 59(a).
(vi) For copper steam pipes-Regulation 35.

For pipes where the ratio between the wall thickness and the diameter would not permit the maintenance of the distance between the flat surfaces specified in the above regulation, this shall be limited to 2/3rd the bore of the pipe.



Reg. 347 B

Cold bend test (for pipes over 102 mm. (4in.) Nominal bore)

strip not less than 38 mm. (1-1/2 in.) wide cut circumferentially from one end of each selected pipe shall when cold withstand, without showing either crack or flaw being doubled over in the direction of original curvature round a bar, the diameter of the bar being:-

For pipes up to and including 10mm (3/8 in.) thick 3 times the    thickness
For pipes over 10mm. thick 4 times the thickness
Earlier text: the 2008 DIPP web edition

Reg. 347 B

Flattening test (for pipes up to and including 102 mm. (4 in.) Nominal bore)

As per requirements of Chapter II.

(i)For cold drawn seamless construction-Regulation 39.

(ii)For hot finished seamless construction-Regulation 44(b).

(iii)For molybdenum seamless construction-Regulation 49 (b).

(iv)For Chrome molybdenum seamless construction-Regulation 54(b).

(v)For electric resistance welded tubes-Regulation 59(a).

(vi)For copper steam pipes-Regulation 35.

For pipes where the ratio between the wall thickness and the diameter would not permit the maintenance of the distance between the flat surfaces specified in the above regulation, this shall be limited to 2/3rd the bore of the pipe.