| Reg. 39 MATERIALS OF CONSTRUCTION COLD DRAWN SEAMLESS CAR BON STEEL BOILER, SUPERHEATER AND HEAT EXCHANGER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F). Flattening Test |
A section of the tube not less than 63 mm in length shall be flattened cold between two parallel flat surfaces to a distance between the plates (H) as calculated by the formula given below, without showing any sign of a crack or flaw. (1 + e) t
H = -----------------
E + t/D where t = specified thickness of tube (mm) D = specified outside diameter of the tube (mm) e = a constant, as given below e = 0.07 for Carbon steel with maximum specified carbon 0.19% or greater e = 0.09 for Carbon steel with maximum specified carbon 0.18% or less |
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
COLD DRAWN SEAMLESS STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F).
Flattening Test
A ring not less than 50 mm in length cut from one end of each selected tube shall be flattened between two parallel flat surfaces to a distance between the plates (H) as calculated by the formula given below without showing any sign of a crack or flaw:
(1+C)a H=--------- a C+ ---- D
where a = thickness of tube (mm)
D = outside diameter of the tube (mm)
C = a constant as given below
C = 0.09 for steel having a specified minimum tensile strength from 31 kgf/mm2 upto and including 35 kgf/mm2.
C = 0.07 for steel having a specified minimum tensile strength over 35 kgf/mm2 upto and including 42 kgf/mm2
C = 0.05 for steel having a specified minimum tensile strength over 42 kgf/mm2 upto and including 50 kgf/mm2.
C = 0.03 for steel having a specified minimum tensile strength over 50 kgf/mm2 upto and including 62 kgf/mm2.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 1969-03-01/1988-12-31 | compilation-1969-1988#p17 OCR of compilation | Substituted | Replaces regulation 39 (flattening test). | listed before the capture | |
| 2001-04-10 | G.S.R. 219 | Substituted | Replaced as part of the block substitution of regulations 36 to 56 (tube specifications). | listed before the capture | |
| 2007-03-12 | G.S.R. 46 (copy) 2008 web edition | Substituted | Substitutes the flattening test: flatten to H = (1+e)t/(e+t/D), with e = 0.07 or 0.09 by carbon content; two-step ductility and soundness test. Uncertain: Text from the unofficial 2008 DIPP web edition; G.S.R. number as published unconfirmed. | listed before the capture |