Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 44 — Tensile strength
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 44 MATERIALS OF CONSTRUCTION SEAMLESS CARBON STEEL PIPES FOR HIGH TEMPERATURE SERVICE FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454 DEGREE C (850 DEGREE F) |
| (a) Tensile test. - Test pieces cut from the ends of the selected pipes shall comply with the following requirements. The tensile test may be carried out on the test pieces cut out from the pipe in the longitudinal direction which shall not be further heat treated nor straightened within the gauge length. As an alternative, pipes may be tested on full cross section.
|
Earlier text: the 2008 DIPP web edition
MATERIALS OF CONSTRUCTION
HOT FINISHED SEAMLESS CARBON STEEL BOILER AND SUPER-HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 450°C (850 °F).
(a)Tensile strength -
(1)The tensile strength of the material cut from finished tubes shall conform to one of the following five grades namely:-
(i)31 to 41 kgf/mm2
(ii)36 to 46 kgf/mm2
(iii)41 to 51 kgf/mm2
(iv)46 to 56 kgf/mm2
(v)50 to 62 kgf/mm2
The upper yield point at room temperature shall not be less than 50% of the specified minimum tensile strength at room temperature.
(2)The minimum values of the stress of proof limit 0.2% at elevated temperature Et of the material may be calculated by multiplying the specified minimum tensile strength at room temperature R20 by the ratio Et/R20 given in the table below:-
Minimum values for the ratio of the stress limit 0.2% at elevated temperature Et to a minimum specified tensile strength at room temperature R20 of carbon steel.
Temperature
*250°C *275°C 300°C 325°C 350°C 375°C 400°C 425°C
Et/R20 0.40 0.38 0.36 0.34 0.33 0.32 0.31 0.30
* For temperature lower than 300°C, any test required for acceptance purpose (in the absence of records of previous tests at these temperatures) shall be made at 300°C in which case the proof stress shall be not less than the value obtained by the calculation from the specified minimum tensile strength at room temperature and the above ratio of 0.36 for 300°C.
(3) The breaking elongation in % shall be not less than 100-Rm
----------
C
Where C = 2.2 for only gauge length of L = 5 do or 5.65 (Ao)¹ᐟ²
do = original diameter of the round test piece.
Ao = original cross section of the rectangular test piece.
NOTE:- C = 1.9 for gauge length of 4 (Ao)¹ᐟ² for test piece in Appendix-B.
(b)Flattening test - A ring not less than 50 mm in length cut from one end of each selected tube shall be flattened between two parallel flat surfaces to a distance between the plates (H) as calculated by the formula given below without showing any sign of a crack or flaw.
(1 + C)a
H = ---------------
a
D
Where, a = thickness of the tube (mm)
D = outside diameter of the tube (mm)
C = a constant as given below
C = 0.09 for steel having a specified minimum tensile strength from 31 kgf/mm2 upto and including 35 kgf/mm2.
C = 0.07 for steel having a specified minimum tensile strength over 35 kgf/mm2 upto and including 42 kgf/mm2
C = 0.05 for steel having a specified minimum tensile strength over 42 kgf/mm2 upto and including 50 kgf/mm2.
C = 0.03 for steel, having a specified minimum tensile strength over 50 kgf/mm2 upto and including 62 kgf/mm2.
(c)Flanging and drift expanding tests - The tube shall withstand either the flanging test or the drift expanding test, at the option of the manufacturer.
(i)Flanging Test.- A test piece cut from the end of the tube in a plane perpendicular to the axis of the tube shall show no crack or flaw after flanging to the specified outside diameter as given in the table below.
(ii)Drift expanding test:- A test piece cut from the end of a tube in a plane perpendicular to the axis of the tube shall show no crack after expanding by a mandrel having an included angle of 30°, 45° or 60° at the option of the manufacturer to increase the outside diameter as given in table below:
Table: Minimum increase of outside diameter of tubes in flanging and drift expanding test.
Type of test Minimum Specified Outside diameter Increase of outside
tensile diameter of the tube
(D) of the tube
strength (s)
Kgf/mm2 A=D< 63.5mm %
B= 63.5<D<150
S<42 A_______________ 17
B 11
A_______________ 14
Flanging test S>42
B 8
Drift expanding A_______________ 17
test B 11Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 2001-04-10 | G.S.R. 219 | Substituted | Replaced as part of the block substitution of regulations 36 to 56 (tube specifications). | listed before the capture | |
| 2004-08-02 | G.S.R. 265 | (a) | Amended | Changes the elongation column heading and corrects the elongation equation. | listed before the capture |