BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 17 — Number of Tensile Tests

Unofficial DPIIT web edition · not verified3 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 17
MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Number of Tensile Tests

(a) Plates – For shell plates, butt straps and plates, gusset plates, end plates, furnace plates and flanging plates one tensile test piece shall be cut from each plate as rolled.

(b) Angle, tee, rivet, and stay bars.- One tensile test shall be made from each 15 or part of 15 bars rolled of each section or diameter from the same charge, but not less than two tensile tests shall be made unless the total number of bars rolled from the same charge is 8 or less than 8 and the bars of the same section or diameter, in which case one tensile test shall suffice. For round bars of 1¾ inches diameter and under, the numbers 50 and 20 shall be substituted for 15 and 8 respectively for determining the number of tests required.

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Number of Tensile Tests

(a)Plates – For shell plates, butt straps and plates, gusset plates, end plates, furnace plates and flanging plates one tensile test piece shall be cut from each plate as rolled.

(b)Angle, tee, rivet, and stay bars.- One tensile test shall be made from each 15 or part of 15 bars rolled of each section or diameter from the same charge, but not less than two tensile tests shall be made unless the total number of bars rolled from the same charge is 8 or less than 8 and the bars of the same section or diameter, in which case one tensile test shall suffice. For round bars of 1¾ inches diameter and under, the numbers 50 and 20 shall be substituted for 15 and 8 respectively for determining the number of tests required.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
1993-10-08G.S.R. 516 OCR of scan(a)SubstitutedReplaces the plate rule: one tensile test piece to be cut from each plate as rolled for shell, butt-strap, gusset, end, furnace and flanging plates.listed before the capture
1993-10-08G.S.R. 516 OCR of scan(b)OmittedOmits sub-regulation (b).listed before the capture
1993-10-08G.S.R. 516 OCR of scan(c)RenumberedRenumbers sub-regulation (c) as sub-regulation (b).listed before the capture

Possible IBR 2026 successors (heading match, unverified): Reg. 38, Reg. 53, Reg. 69, Reg. 153, Reg. 159, Reg. 253, Reg. 365, Reg. 437, Reg. 509