Regulation 90 — Transverse test

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 90
MATERIALS OF CONSTRUCTION

GENERAL GREY IRON CASTINGS (GRADE A)

Transverse test

A transverse test bar cast in accordance with Regulation 88(a)must when placed on supports set at the distance shown in column 2 of the following table sustain a load applied at the centre of not less than that shown in column 3 and must show before rupture a deflection not less than that shown in column 4. The supports and the point of application of the load shall be rounded to a radius of not less than 1/8 inch.

Diameter of test bar 
(1)
Distance between Support 
(2)
Minimum breaking load – Grade A 
(3)
Minimum deflection – Grade A 
(4)
Inches Inches lbs.
Inch

0.6 9 530 0.07
0.875 12 1,185 0.10
1.2 18 1,950 0.15
1.6 18 4,280 0.12
2.1 24 6,660 0.15

If the diameter of a transverse test bar as cast varies within the limits specified in Regulation 88(a) the equivalent breaking load for the test bar of standard diameter shall be calculated in accordance with the given factors in Appendix F.

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

GENERAL GREY IRON CASTINGS (GRADE A)

Transverse test

A transverse test bar cast in accordance with Regulation 88(a) must when placed on supports set at the distance shown in column 2 of the following table sustain a load applied at the centre of not less than that shown in column 3 and must show before rupture a deflection not less than that shown in column 4. The supports and the point of application of the load shall be rounded to a radius of not less than 1/8 inch.

Diameter of test Distance between  Minimum breaking load – Minimum deflection –
bar (1)         Support (2)        Grade A (3)            Grade A (4)

Inches          Inches             lbs.                   Inch

0.6             9                  530                    0.07
0.875           12                 1,185                  0.10
1.2             18                 1,950                  0.15
1.6             18                 4,280                  0.12
2.1             24                 6,660                  0.15

If the diameter of a transverse test bar as cast varies within the limits specified in Regulation 88

(a)the equivalent breaking load for the test bar of standard diameter shall be calculated in accordance with the given factors