Regulation 88 — Dimension of test bars

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 88
MATERIALS OF CONSTRUCTION

GENERAL GREY IRON CASTINGS (GRADE A)

Dimension of test bars

(a) Transverse Test Bars.- The transverse test bars of the diameter specified by the Inspecting Authority according to the main cross sectional thickness of the casting represented, shall conform to the following dimensions:

Diameter of test Bar
Limits of Diameter
Over all length
Main cross-sectional thickness of castings represented
Inch
inch Inches Inches
0.6
+0.045
10 Not exceeding 3/8
0.875
+0.065
15 Over 3/8 and not exceeding 3/4
1.2
+0.090
21 Over3/4 and not exceeding 1 1/8
1.6
+0.10
21 Over 1 1/8 and not exceeding 1 5/8
2.1
+0.10
27 Over 1 5/8

Bars cast to a size in excess of the limits given above may be machined to a diameter within the specified limits. Bars cast within these limits of diameter may also be machined before the transverse test is made, providing that the finished diameter falls within these limits.

(b) Tensile Test Bars.- The tensile test bars of the diameter specified by the Inspecting Authority, according to the main cross-sectional thickness of the casting represented shall conform to the dimensions shown in the following table. Bars may be tested with either plain or screwed ends.

The test bars shall be cast as parallel bars of the diameters given in Column B and then machined to the dimensions C and P in the above table.

(c) For castings over 2 inches in thickness a test bar of larger diameter than 2.1 inches may be used by agreement between the manufacturer and the Inspecting Authority. For diagram and table see under clause (b) of this Regulation.

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

GENERAL GREY IRON CASTINGS (GRADE A)

Dimension of test bars

(a)Transverse Test Bars.- The transverse test bars of the diameter specified by the Inspecting Authority according to the main cross sectional thickness of the casting represented, shall conform to the following dimensions:

Diameter of test  Limits of    Over all Main cross-sectional thickness of castings
     Bar         Diameter      length                 represented
     Inch           inch       Inches                   Inches
     0.6           +0.045        10                Not exceeding 3/8
    0.875          +0.065        15           Over 3/8 and not exceeding 3/4
     1.2           +0.090        21          Over3/4 and not exceeding 1 1/8
     1.6           +0.10         21         Over 1 1/8 and not exceeding 1 5/8
     2.1           +0.10         27                    Over 1 5/8

Bars cast to a size in excess of the limits given above may be machined to a diameter within the specified limits. Bars cast within these limits of diameter may also be machined before the transverse test is made, providing that the finished diameter falls within these limits.

(b)Tensile Test Bars.- The tensile test bars of the diameter specified by the Inspecting Authority, according to the main cross-sectional thickness of the casting represented shall conform to the dimensions shown in the following table. Bars may be tested with either plain or screwed ends.

The test bars shall be cast as parallel bars of the diameters given in Column B and then machined to the dimensions C and P in the above table.

(c)For castings over 2 inches in thickness a test bar of larger diameter than 2.1 inches may be used by agreement between the manufacturer and the Inspecting Authority. For diagram and table see under clause (b) of this Regulation.