Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 584 — Girder sling stays
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 582, 583. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 582, Reg. 583, Reg. 584 | |||||||||||||||||||
Reg. 583 Girders for fire-box and combustion chamber crowns
Reg. 584 Girder sling stays
| |||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Girder sling stays
For slung girders the proportion of slings, links, pins and connections to the shell shall be sufficient to carry the whole load that would otherwise be carried on the toes of the girders and for any of the above parts in tension a stress of 9,000 pounds per square inch of net section, and for parts in shear a stress of 8,000 pounds per square inch of net section shall not be exceeded. In the case of parts in double shear, the net area of the section should be taken as 1.875 times the single section.