Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 575 — Flat crown plates for vertical boilers
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 576, 577, 577A, 577B. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 575, Reg. 576, Reg. 577 a, Reg. 577 b
| ||||||||||||||||||
Reg. 576 Wide water spaces between and around tube nests
Reg. 577 Flat tube plates and tube nests a) Stay tubes and plain tubes
Reg. 577 b Parts of flat plates within tube nests
| ||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Flat crown plates for vertical boilers
i)Flat crown plates shall be supported by the uptake and/ or bar stays .
ii)The inside radius of curvature of the flange to the shell or fire box shall be not less than four times the thickness of the plate and in no case less than 63 mm where the plate is flanged for attachment to the uptake, the inside radius of curvature of the flange shall be not less than twice the thickness of the plate and in no case less than 25 mm.
iii)The thickness of flat crown plates shall be determined in accordance with Regulation 574.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 1996-12-06 | G.S.R. 59 OCR of scan | Substituted | Replaces regulation 575 on flat crown plates of vertical boilers (support, flange radii, thickness per 574). | listed before the capture |