Reg. 573 Stand Pipes and branches-
Reg. 574 Stayed Flat surfaces (other than Crowns of Vertical Boilers). Stayed heads/ Braced and stayed surfaces.
| |||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Stand Pipes and branches-
a)The thickness and bolting of all flanges for joining the mountings and fittings shall be in accordance with the dimensions as laid down in Appendix- E to these regulations. In no case, however, shall the thickness of flanges be less than 13 mm.
b)(i) The Wall thickness of nozzles and other connections shall not be less than that specified for the applicable loading, namely, internal pressure, bending and static loads.
(ii)The pressure loading shall be determined by regulation 564, but in no case shall the thickness be less than that calculated by the following formula:-
t = 0.04D + 2.5 mm (equation XII/10)
where, t is the thickness of standpipe and D is the outside diameter of connection. If the branch is connected by screwing, the thickness ‘t’ shall be measured at the root of the thread.
c)Where a double flanged steam pipe is tapered, the thickness of flange joining the boiler and fitting shall correspond to the bore of pipe at the flange connection in accordance with Appendix-E to these regulations.