Regulation 391A — Aging of boilers

Unofficial DPIIT web edition · not verified7 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette

Reg. 391 A

Aging of boilers

a) Shell Type Boilers:-

(i) In order to take the aging effect on boilers, the working pressure of the parts of them as calculated from the formulae in these regulations shall be reduced as per the table given below:-

Age of boiler exceeding
(in years)
25 35 45 50 60 70 80 90 100
Maximum permitted working pressure percent. 95 90 85 80 70 60 50 40 30
(ii) For those boilers the plates of which have already been cut and tested shall be given a further lease of life of fifty years from the date of the test of the boilers. The working pressure that shall be allowed after the testing shall be reduced as per the table given below:-

Period after date of test
(in years)
10 20 30 40 50
Maximum working pressure
allowed (percentage)
90 80 70 50 30
b) Water Tube Boilers: -

(i) The boilers which are operating at a temperature of 400°C and above including utility or industrial boilers and all boiler parts operating in the creep range of the boiler shall be non-destructively tested as per the table 1 given below after they are in operation for 1,00,000 hours for assessment of the remnant life of the parts;
(ii) The parts of a boiler when it completes a life of twenty five years are to be tested as per table 2 for assessment of the remnant life of such parts. If results are acceptable as per the standards laid down by the Central Boilers Board, a certificate shall be issued by the Chief Inspector of Boilers for extending the life of the boiler for a further period of ten years or such less period as recommended by the Remnant Life Assessment Organisation. This assessment of remnant life shall be carried out thereafter every five years by the organisations working in the field of boilers and remnant life and extension thereof after such organisation is approved by the Central Boilers Board. Such organisation shall work in close coordination with the office of the Chief Inspector of Boilers in the field of remnant life assessment and extension. The working pressure of such boilers may be reduced on the recommendations of such approved organisation.

Notwithstanding anything contained in this regulation, for boilers working at a pressure less than 50 kg/cm2, such elaborate remnant life assessment is not mandatory.  However, in such cases, drums and headers of such boilers shall be inspected by Ultrasonic testing, Magnetic particle testing and Dye penetrant test.

Next>>>
Earlier text: the 2008 DIPP web edition

Aging of boilers

a)Shell Type Boilers:-

(i)In order to take the aging effect on boilers, the working pressure of the parts of them as calculated from the formulae in these regulations shall be reduced as per the table given below:-

Age of boiler exceeding
                           25 35 45 50 60 70 80 90 100
(in years)
Maximum permitted working
                           95 90 85 80 70 60 50 40 30
pressure percent.

(ii)For those boilers the plates of which have already been cut and tested shall be given a further lease of life of fifty years from the date of the test of the boilers. The working pressure that shall be allowed after the testing shall be reduced as per the table given below:-

Period after date of test
                          10 20 30 40 50
(in years)
Maximum working pressure
                          90 80 70 50 30
allowed (percentage)

b)Water Tube Boilers: -

(i)The boilers which are operating at a temperature of 400°C and above including utility or industrial boilers and all boiler parts operating in the creep range of the boiler shall be non-destructively tested as per the table 1 given below after they are in operation for 1,00,000 hours for assessment of the remnant life of the parts;

(ii)The parts of a boiler when it completes a life of twenty five years are to be tested as per table 2 for assessment of the remnant life of such parts. If results are acceptable as per the standards laid down by the Central Boilers Board, a certificate shall be issued by the Chief Inspector of Boilers for extending the life of the boiler for a further period of ten years or such less period as recommended by the Remnant Life Assessment Organisation. This assessment of remnant life shall be carried out thereafter every five years by the organisations working in the field of boilers and remnant life and extension thereof after such organisation is approved by the Central Boilers Board. Such organisation shall work in close coordination with the office of the Chief Inspector of Boilers in the field of remnant life assessment and extension. The working pressure of such boilers may be reduced on the recommendations of such approved organisation.

Notwithstanding anything contained in this regulation, for boilers working at a pressure less than 50 kg/cm², such elaborate remnant life assessment is not mandatory. However, in such cases, drums and headers of such boilers shall be inspected by Ultrasonic testing, Magnetic particle testing and Dye penetrant test.

Next>>>

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
1994-11-23G.S.R. 607 OCR of scanSubstitutedReplaces regulation 391A on ageing of boilers: pressure-reduction tables for shell boilers and residual life assessment for water tube boilers.listed before the capture
1998-11-10G.S.R. 221 OCR of scan(a)(ii)SubstitutedReplaces item (ii): boilers with plates cut and tested get 50 more years of life with working pressure reduced 90-30% per table.listed before the capture
1998-11-10G.S.R. 221 OCR of scan(b)(i), (ii)SubstitutedReplaces items: NDT of boilers at 400 C and above after 100,000 hours (Table 1); 25-year life assessment and 10-year extensions by approved organisations (Table 2).
Uncertain: Temperature printed '400.0' (400 deg C).
listed before the capture
2001-12-10G.S.R. 672(b)InsertedAdds that for boilers below 50 kg/cm2 full remnant life assessment is not mandatory, but drums and headers must be checked by UT, MPI and dye penetrant.listed before the capture
2005-01-19G.S.R. 32(b)(ii)AmendedSubstitutes 'Chief Inspector of Boilers' for 'Technical Adviser (Boilers)'.listed before the capture
2015-04-15G.S.R. 286(E)SubstitutedReplaces regulation 391A (ageing of boilers).listed before the capture
2020-09-11G.S.R. 551(E)(a)(iii)InsertedInserts sub-clause (iii) on shell type waste heat boilers (unfired).check the text