| Reg. 371, Reg. 372 Pipe work supports
Reg. 372 Drainage
| |||||||||||
Earlier text: the 2008 DIPP web edition
Drainage
a)In the case of steam mains, attention should be paid to the adequate provision of drainage points in the form of drain pockets. Drainage points connected to streamtraps, shall be provided wherever water can collect under working conditions. Hand drains shall be provided at all points at which water can collect in any portion of the steam main, by valve leakage or other means, when shut down, or when warming up prior to use.
b)Where practicable a suitable gradient shall be provided in the pipe work to ensure the passage of condensed water in the direction of flow of steam towards the drainage point.
c)It is recommended that a by pass should be fitted at each steam-trap.
d)Where the volume of water deposited is likely to be of serious proportions, separator should be installed. Each separator shall be furnished with a steam trap which shall be connected to it by means of a three-way cock one end of which is connected to a manually operated drain.