Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 240C — Tensile test
Text in the 2008 DIPP web edition
saved copy p.248, as amended to about 2005 (later amendments below are not merged; units as printed).
Tensile test
(i)The tensile strength and percentage elongation shall be in accordance with the requirements of regulation 9 and 16.
(ii)The upper yield point at room temperature shall be not less than 50% of the specified minimum tensile strength at room temperature. The minimum values of the stress at proof limit 0.2% at elevated temperature (Et) of the material may be calculated by multiplying the minimum specified tensile strength at room temperature (R20) by the value of the ratio (Et/R20) given in the table under regulation 16.
(iii)
100-Rm
The breaking elongation in percentage shall be not less than
2.2
where,
Rm = tensile strength at room temperature, in kgf/mm² 100 = quality index 2.2 = a constant which is valid only when Lo = 5 do
where,
do = original diameter of round test piece”.
Lo = gauge length