Tensile test

(i)The tensile strength and percentage elongation shall be in accordance with the requirements of regulation 9 and 16.

(ii)The upper yield point at room temperature shall be not less than 50% of the specified minimum tensile strength at room temperature. The minimum values of the stress at proof limit 0.2% at elevated temperature (Et) of the material may be calculated by multiplying the minimum specified tensile strength at room temperature (R20) by the value of the ratio (Et/R20) given in the table under regulation 16.

(iii)
                                                             100-Rm
     The breaking elongation in percentage shall be not less than
                                                               2.2

where,

Rm = tensile strength at room temperature, in kgf/mm² 100 = quality index 2.2 = a constant which is valid only when Lo = 5 do

where,

do = original diameter of round test piece”.