BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 16 — Tensile tests

Unofficial DPIIT web edition · not verified1 amendment found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
Reg. 16
MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Tensile tests

(a) The tensile strength of different grades of material shall be within the limits specified in regulation 9 (d).

(b) – The upper yield point at room temperature shall be not less than 50% of the specified minimum tensile strength at room temperature.

(c) – The breaking elongation in percentage shall be not less than ( N-Rm)/C   

Where Rm = Tensile strength at room temperature in kgf/mm2

N = a quality index of 100 for plate thickness upto 50 mm or  95 for plate

 thickness over 50mm.

C = 2.2 for only gauge lengths of L=5 do or L=5.65/ ÖAo      

 Where Lo = gauge length             

Ao = original cross section of the rectangular test piece.

do = original diameter of the round test piece.

NOTE: C= 1.9 for gauge lengths of 4 ÖAo for test piece of Appendix-B.   

(d) – The minimum values of the stress at proof limit 0.2% at elevated temperature (Et) may be calculated by multiplying the minimum specified tensile strength at room temperature (R20) by the value of the ratio (Et/R20) given in the table below:

TABLE

Minimum values for the ratio of the stress at proof limit 0.2% at elevated temperature (Et) to the minimum specified tensile strength at room temperature (R20) of carbon steel boiler plates.

Temperature 250°C *275°C 300°C 325°C 350°C 375°C
Et/R20 0.40 0.38 0.36 0.34 0.33 0.32
Temperature 400°C 425°C
Et/R20 0.31 0.30

*For temperatures lower than 300°C any test required for acceptance purposes (in the absence of records of previous tests at these temperatures) shall be made at 300°C, in which case the proof stress shall be not less than value obtained by calculation from the specified minimum tensile strength at room temperature and the above proof-ratio of 0.36 for 300°C.

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

STEEL PLATES, RIVETS, SECTION AND BARS IN CARBON STEEL

Tensile tests

(a)The tensile strength of different grades of material shall be within the limits specified in regulation 9 (d).

(b)– The upper yield point at room temperature shall be not less than 50% of the specified minimum tensile strength at room temperature.

(c)– The breaking elongation in percentage shall be not less than ( N-Rm)/C

Where Rm = Tensile strength at room temperature in kgf/mm²

N = a quality index of 100 for plate thickness upto 50 mm or  95 for plate
thickness over 50mm.

C = 2.2 for only gauge lengths of L=5 do or L=5.65/ √Aο

Where Lο = gauge length

Aο = original cross section of the rectangular test piece.

dο = original diameter of the round test piece.

NOTE: C= 1.9 for gauge lengths of 4 √Aο for test piece of Appendix-B.

(d)– The minimum values of the stress at proof limit 0.2% at elevated temperature (Et) may be calculated by multiplying the minimum specified tensile strength at room temperature (R20) by the value of the ratio (Et/R20)

Minimum values for the ratio of the stress at proof limit 0.2% at elevated temperature (Et) to the minimum specified tensile strength at room temperature (R20) of carbon steel boiler plates.

Temperature       250°C    *275°C    300°C     325°C    350°C    375°C
Et/R20            0.40     0.38      0.36      0.34     0.33     0.32
Temperature       400°C    425°C
Et/R20            0.31     0.30

*For temperatures lower than 300°C any test required for acceptance purposes (in the absence of records of previous tests at these temperatures) shall be made at 300°C, in which case the proof stress shall be not less than value obtained by calculation from the specified minimum tensile strength at room temperature and the above proof-ratio of 0.36 for 300°C.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
2015-04-15G.S.R. 286(E)(d)AmendedBases maximum permissible stress on the governing code of the material's country.listed before the capture