Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 192 — Dished shell and firebox crowns
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 190, 191. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 190, Reg. 191, Reg. 192 DISHES END PLATES Dished ends subject to external pressure In the case of unstayed dished ends, for the co-efficient 15 in equation (24) the cofficient 12 shall be substituted and R shall be the outer radius of curvature of plate which shall not exceed the external diameter of the shell to which it is attached. For plates exposed to furnace flame the co-efficient shall be 10.5.
Reg. 191 DISHES END PLATES Dished ends of Lancashire and Cornish Type Boilers
Reg. 192 DISHES END PLATES Dished shell and firebox crowns
|
Earlier text: the 2008 DIPP web edition
DISHES END PLATES
Dished shell and firebox crowns
a)In determining the working pressure in accordance with Regulations 189 and 190 no accounts shall be taken of the influence of the up-take tube in vertical boilers. If dished crown plates having uptakes are fit for higher pressures, when considered as flat plates, under Reg.197 such higher pressure shall be allowed.
b)The radius R of the dished part may be found as follows : -
C² + H²
R = Eqn.(27)
2H
C and H are the lengths in inches of half the base line or chord on which H measured and the height of the dish or camber at the middle of the chord respectively.