Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 190 — Dished ends subject to external pressure
Unofficial DPIIT web edition · not verified0 amendments found
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 191, 192. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
| Reg. 190, Reg. 191, Reg. 192 DISHES END PLATES Dished ends subject to external pressure In the case of unstayed dished ends, for the co-efficient 15 in equation (24) the cofficient 12 shall be substituted and R shall be the outer radius of curvature of plate which shall not exceed the external diameter of the shell to which it is attached. For plates exposed to furnace flame the co-efficient shall be 10.5.
Reg. 191 DISHES END PLATES Dished ends of Lancashire and Cornish Type Boilers
Reg. 192 DISHES END PLATES Dished shell and firebox crowns
|
Earlier text: the 2008 DIPP web edition
DISHES END PLATES
Dished ends subject to external pressure
In the case of unstayed dished ends, for the co-efficient 15 in equation (24) the cofficient 12 shall be substituted and R shall be the outer radius of curvature of plate which shall not exceed the external diameter of the shell to which it is attached. For plates exposed to furnace flame the co-efficient shall be 10.5.
R
In no case shall exceed 2.75
t