Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 108 — Longitudinal Seams
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 109, 110. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 108, Reg. 109, Reg. 110 SHELLS, ANGLE RINGS, BUTT STRAPS, ETC. Longitudinal Seams |
| The longitudinal seams of shell belts shall be butt-jointed with double straps when the diameter or Working Pressure exceeds the limits stated below :-
Butt straps shall be cut from the shell plates, or, alternatively, all the butt straps of each required thickness shall be cut from one plate. The lengths of the straps wherever practicable shall be transverse to the direction of rolling of the plate. Straps shall be pressed or bent in rolls to the shell curvature. Reg. 110 SHELLS, ANGLE RINGS, BUTT STRAPS, ETC. Thinning of Butt Straps |
Earlier text: the 2008 DIPP web edition
SHELLS, ANGLE RINGS, BUTT STRAPS, ETC.
GENERAL
Longitudinal Seams
The longitudinal seams of shell belts shall be butt-jointed with double straps when the diameter or Working Pressure exceeds the limits stated below :-
Type of Boiler When diameter exceeds When Working Pressure
(feet) exceeds
(lbs/sq. inch)
Loco Types 2½ 200
Vertical Types 6 125
Other Types 6 80Possible IBR 2026 successors (heading match, unverified): Reg. 81, Reg. 97, Reg. 103, Reg. 172, Reg. 479