Reg. 61
MATERIALS OF CONSTRUCTION

Hydraulic test


(a) Each tube shall be hydraulically tested at the makers’ works and shall withstand a hydraulic pressure to one and half times, the design pressure, subject to a minimum of 1.00 kg/mm sq. and for tube OD larger than 101 mm outside diameter minimum of 0.8 kg/mm sq.  However, the test pressure shall not be greater than the pressure calculated by the following formula. 

             2 S t
P  =  -------------
          D

Where P = test pressure  (in kg/mm sq.)

           D = specified outside diameter of the tube

            t   = specified wall thickness

            S = stress (in kgf/mm sq.) which shall be taken as 40% of the specified minimum tensile strength at room temperature.

(b) Notwithstanding anything contained in the above regulation, the hydraulic test at the maker’s works may be dispensed with, provided that the tubes are subjected to non destructive testing by an appropriate method like Ultrasonic or Eddy current testing.

 

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

ELECTRICAL -RESISTR|ANCE -WELED STEEL BIOLER AND SUPER-HEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454⁰ C (850⁰ F)

Hydraulic test

(a)Each tube shall be hydraulically tested at the makers’ works and shall withstand a hydraulic pressure to one and half times, the design pressure, subject to a minimum of 1.00 kg/mm sq. and for tube OD larger than 101 mm outside diameter minimum of 0.8 kg/mm sq. However, the test pressure shall not be greater than the pressure calculated by the following formula.

2 S t
P = -------------
D
Where P = test pressure (in kg/mm sq.)
           D = specified outside diameter of the tube
           t = specified wall thickness
           S = stress (in kgf/mm sq.) which shall be taken as 40% of the specified minimum
           tensile strength at room temperature.

(b)Notwithstanding anything contained in the above regulation, the hydraulic test at the maker’s works may be dispensed with, provided that the tubes are subjected to non destructive testing by an appropriate method like Ultrasonic or Eddy current testing.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
1969-03-01/1988-12-31compilation-1969-1988#p27 OCR of compilationSubstitutedReplaces regulation 61 (hydraulic test of tubes).
Uncertain: Body number reads '67' in OCR; heading reads 61.
listed before the capture
1994-11-23G.S.R. 607 OCR of scan(a)AmendedAdds a proviso allowing the test to be dispensed with if the tube undergoes ultrasonic and/or eddy current testing.listed before the capture
1999-10-14G.S.R. 345SubstitutedReplaced as part of the block substitution of regulations 57 to 63A (electrically welded tubes).listed before the capture