BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 591E — Weld attachment

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 591C, 591D. This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]

Reg. 591 c, Reg. 591 d, Reg. 591 e

Link stays

Link stays shall be so arranged that the angle “V”  (Fig. XII/83) is not less than 60° and the dimensions shall be such that the stress in the stay at its weakest part does not exceed one-seventh of the minimum tensile stress of the plate used.



Reg. 591 d

Anchor plates angles, link pins and the like members

The strength of anchor plates, angles and link pins calculated at the weakest section shall be as follows:-

(i)

Link pins shall be so designed that the shear stress does not exceed 8,000 pounds per square inch, the strength of pins in double shear being taken as 1.875 times the strength of pins in single shear.

(ii)

Anchor plates or angles shall be so designed that the calculated stress does not exceed one-seventh of the minimum tensile stress of the material used, but in no case shall the thickness be less than seven-eighth of the thickness of the shell plate with a minimum of ½ inch, nor the length of the portion attached to the end plate be less than the distance between the lines of end to shell flat margin and the breathing space line around the flues or tube nests.


Reg. 591 e

Weld attachment

Where gusset plates, anchor plates or angles are welded to the shell and/or end plates, the attachment shall be by means of continuous fillet welds on each side or by butt welds prepared in accordance with paragraph 2, details 1, m, n, or p of Appendix A of this Chapter.

The welds shall be of such dimensions that the stress calculated on an area equal to the effective length of the weld multiplied by the effective throat thickness shall not exceed that permitted for the parent metal multiplied by the appropriate weld factor in Table XII/7

The effective length of a weld shall be taken as that length of weld which is of the specified size throughout.

For open-ended fillet welds the effective length shall be the overall length less twice the weld size.

For the purpose of stress calculation the effective throat thickness of a butt weld shall be taken as the thickness of the gusset or anchor plate and the effective throat thickness of fillet weld shall be taken as 0.7 of the fillet size. For compound welds the effective throat thickness shall be the sum of those of the constituent parts.

TABLE XII/7
Weld Attachments

Form of weld

Weld factor

Not stress relieved Stress relieved
Single J or bevel butt-welds (with or without superimposed fillet. Unsealed
Sealed
0.35
0.60
0.45
0.70
Double J or bevel butt-welds [with or without super-imposed fillet(s)] 0.60 0.70
Double fillet welds 0.55 0.65
[image] [image]
[image] [image] [image]
Message from Chairman of Central Boilers Board • About Central Boiler Board • History of Indian Boiler Regulations • Foreword • Contents Chapter Wise • Contents Regulation Wise • List of Amendments
• Indian Boilers Act 1923 • Ibr Forms • Home • Search • Help • Contact Us
Earlier text: the 2008 DIPP web edition

Weld attachment

Where gusset plates, anchor plates or angles are welded to the shell and/or end plates, the attachment shall be by means of continuous fillet welds on each side or by butt welds prepared in accordance with paragraph 2, details 1, m, n, or p of Appendix A of this Chapter.

The welds shall be of such dimensions that the stress calculated on an area equal to the effective length of the weld multiplied by the effective throat thickness shall not exceed that permitted for the parent metal multiplied by the appropriate weld factor in Table XII/7

The effective length of a weld shall be taken as that length of weld which is of the specified size throughout.

For open-ended fillet welds the effective length shall be the overall length less twice the weld size.

For the purpose of stress calculation the effective throat thickness of a butt weld shall be taken as the thickness of the gusset or anchor plate and the effective throat thickness of fillet weld shall be taken as 0.7 of the fillet size. For compound welds the effective throat thickness shall be the sum of those of the constituent parts.

                                TABLE XII/7
                             Weld Attachments
           Form of weld                          Weld factor
                                  Not stress relieved    Stress relieved
Single J or bevel butt-welds (with or  Unsealed  0.35    0.45
without superimposed fillet.      Sealed       0.60      0.70
Double J or bevel butt-welds [with or          0.60      0.70

without super-imposed fillet(s)]

Double fillet welds                            0.55      0.65