BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 591A — Load on each stay

Unofficial DPIIT web edition · not verified0 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 591, 591B. This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]

Reg. 591, Reg. 591 A, Reg. 591 B

Gusset Link, Brace and Similar Stays

For welded Lancashire, Cornish and cylindrical horizontal multi-tubular type boilers, all welded gusset stays shall not be used. To ensure flexibility, link stays, bar stays, brace stays and other similar stays or suitably designed gusset stays other than the all-welded type shall be used. All welded gusset stays, however, may be used in cylindrical horizontal waste heat and cylindrical vertical multitubular boilers.

Welded gusset stays and braces may be used for welded Lancashire, Cornish and Cylindrical Horizontal Multi-tubular boilers provided their method of attachment is approved by the Inspecting Authority.



Reg. 591 a

Load on each stay

Each gusset or link stay supporting the flat end plate of a boiler shall be designed to carry the whole load due to pressure on the area it supports. The area supported by any one stay shall be obtained by considering the total area to be supported which lies within the limits of the flat plate margins and dividing this area by boundary lines drawn between the stays. These boundary lines shall be at all points equidistant from the adjacent points of support in the area under consideration.

The effective uniformly distributed load on a triangular gusset plate or on a diagonal link stay shall be assumed to be equal to the perpendicular load on the portion of the end plate to be supported (determined as above) multiplied by L/L1 (see Figs. XII/81, XII/82, XII/83).



Reg. 591 b

Gusset plates

Gusset plates shall be so proportioned that the angle “V”  (see Figs. XII/81 and XII/82), is not less than 60°.

The thickness of the gusset plate shall be such that the stress in the plate to withstand the effective uniformly distributed load (as defined above) calculated on the smallest cross-section on Line XX or YY (Figs. XII/81 and XII/82, shall not exceed one-seventh of the minimum tensile stress of the plate used but in no case shall be the thickness be less than seven-eighths of the thickness of the shell plate with a minimum of 7/16 inch.

Where all-welded gusset stays are used a stiffening plate shall be welded at the toe of the gusset where it is secured to the end plate (i.e., where the maximum stress occurs) (see Fig. XII/81).

[image] [image]
[image] [image] [image]
Message from Chairman of Central Boilers Board • About Central Boiler Board • History of Indian Boiler Regulations • Foreword • Contents Chapter Wise • Contents Regulation Wise • List of Amendments
• Indian Boilers Act 1923 • Ibr Forms • Home • Search • Help • Contact Us
Earlier text: the 2008 DIPP web edition

Load on each stay

Each gusset or link stay supporting the flat end plate of a boiler shall be designed to carry the whole load due to pressure on the area it supports. The area supported by any one stay shall be obtained by considering the total area to be supported which lies within the limits of the flat plate margins and dividing this area by boundary lines drawn between the stays. These boundary lines shall be at all points equidistant from the adjacent points of support in the area under consideration.

The effective uniformly distributed load on a triangular gusset plate or on a diagonal link stay shall be assumed to be equal to the perpendicular load on the portion of the end plate to be supported (determined as above) multiplied by L/L1 (see Figs. XII/81, XII/82, XII/83).