Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 579B
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 578, 579, 579A. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 578, Reg. 579 A, Reg. 579 B | ||||||||||
Reg. 579 Plain tubes (a) Attachment
| ||||||||||
Earlier text: the 2008 DIPP web edition
Manhole openings in flat plates
Where manholes are located in flat plates, the opening shall be suitably compensated.
Compensation shall be obtained by flanging the edge of the opening, or by providing a fabricating ring (see Figs. XII/52, XII/53, XII/54, XII/55, and XII/56 ).
The manhole in the lower portion of the flat front end plates shall be fitted with a flanged strengthening ring, the thickness of the flat portion of which shall be not less (1.5T +1/8 inch)
Where T=the thickness of the end plate in inches, and in boilers of 7 feet and 6 inches diameter and over the manhole frame shall be fitted with a peak to reinforce the portion of the end plate between and below the furnaces and this peak shall be securely welded there to.
In all cases the depth of the flanging or ring shall not be less than that determined by Equation XII/6.
NOTE:-Where the manhole is located in or between tube nests in Multi-tubular boilers or below the furnaces of other Boilers the stay tubes in the boundary rows, or the gusset stays, as applicable, shall be arranged as closely as practicable to the manhole.