Reg. 566 Dished end plates for Lancashire and Cornish boilers
| |||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Dished end plates for Lancashire and Cornish boilers
For the dished ends of Lancashire and Cornish boilers without stays and subject to internal pressure the maximum working pressure shall be determined by the following formula:-
(t-8)30 x S
WP = Equation XII/5
R
Where,
t is minimum thickness of the end plate in thirty-seconds of an inch
WP is working pressure in pounds per square inch.
R is inner radius of curvature of the end plate in inches
S is minimum tensile strength of the plate in tons per square inch.
The inner radius of curvature of the end plate shall not exceed 1 ½ times the external
diameter of the shell to which it is attached.
The inner radius of flanging of the end plate shall be not less than 4 times the thickness of the plate but in no case less than 2 ½ inches.
Where the end plate has a manhole, compensation shall be obtained by flanging the edge of the opening or by providing a fabricated ring (see Fig. XII/52).
In either case the depth of the flanging or ring measured at the minor axis shall not be less than that determined by the following formula:-
D = √TW Equation XII/6
Where,
D is depth of flange or ring in inches, measured from the outside of the plate to the joint face.
T is thickness of the plate in inches.
W is width of the opening in inches, measured on the minor axis.