Regulation 551 — Girder stays for Firebox and Combustion Chamber Crowns
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 552, 553. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 551, Reg. 552, Reg. 553 | |||||||||||||||||||||||||||||||||||||
Reg. 552 Gusset stays
Reg. 553 Access
| |||||||||||||||||||||||||||||||||||||
Earlier text: the 2008 DIPP web edition
Girder stays for Firebox and Combustion Chamber Crowns
Where girder stays are attached with stay bolts and nuts, they shall be bedded to the corners or ends of side plates.
The attachment of girder stays welded directly to the crown plates shall comply with Figures XII/47, XII/48, XII/49, XII/50 or XII/51. Such girders shall be welded to the crown plate prior to stress-relieving.
Each girder shall be of sufficient strength to support its due proportion of the load on the crown plate independently of the crown plate, and the bolts or weld attachments shall have sufficient cross-sectional area to carry the applied load.
The waterways between the underside of the girder and the crown plate shall be as large as practicable, but in no case less than 1 ½ inches deep.