Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 512 — Economiser water outlet temperature
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine); the same page also prints regulations 513, 514. The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
|
Constructional Requirements | |||||
| |||||
|
STEEL ECONOMISER WITH OR WITHOUT CAST IRON SLEEVES ON THE TUBES | |||||
| |||||
|
STEEL ECONOMISER WITH OR WITHOUT CAST IRON SLEEVES ON THE TUBES | |||||
|
Earlier text: the 2008 DIPP web edition
STANDARD CONDITIONS FOR THE DESIGN AND CONSTRUCTION OF ECONOMIZER, FEED PIPES, FEED HEATERS AND OTHER SIMILAR VESSELS
CONSTRUCTIONAL REQUIREMENTS
Economiser water outlet temperature
The design conditions shall be such that the maximum outlet water temperature of the economiser shall be at least 40°F below the saturated steam temperature in the boiler drum:
Provided that this requirement shall not apply to economisers used on low pressure water heating systems working at pressure less than 120 ft. head of water.