Regulation 51 — Hydraulic test.

Unofficial DPIIT web edition · not verified2 amendments found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]
Reg. 51
MATERIALS OF CONSTRUCTION

SEAMLESS FERRITIC AND AUSTENITIC ALLOY STEEL BOILER, SUPERHEATER AND HEAT EXCHANGER TUBES

Hydraulic test

(i) Each tube shall be tested by the manufacturer and shall withstand a hydraulic pressure to one and a half time the design pressure subject to a minimum of 1.00 kgf/mm2, but not greater than pressure calculated by the following formula:-

           P = 2 St/D

where  P = test Pressure

           D = specified out side diameter of the tube

           t = specified wall thickness of the tube

           S = stress which shall be taken as 40% of the minimum tensile strength at room temperature for carbon and ferritic steel and 80% of the minimum yield strength at room temperature for austenitic stainless steel

(ii)  Notwithstanding anything contained in the above clause, the hydraulic test at the maker's works may be dispensed with, provided that the tubes are subject to non destructive testing by an appropriate method like Ultrasonic or Eddy current or Stray Flux testing.

[image][image]
[image][image][image]

Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

SEAMLESS MOLYBDENUM STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 510 DEGREE C (950 DEGREE F).

Hydraulic test

Each tube shall be tested at the Maker’s works on completion of manufacture and shall withstand a hydraulic pressure, to one and a half times the design pressure subject to a minimum of 0.70 kgf/mm2 but not greater than the pressure calculated by the following formula:

           2 St
           P = -----------
           D

              P = test pressure
              D = outside diameter of the tube
Where         t = nominal wall thickness of the tube
              S = stress, which shall be taken as 40% of the minimum tensile strength at
              room temperature.

(ii)Notwithstanding anything contained in clause (i), the hydraulic test for tubes in Makers’ premises may be dispensed with by the Inspecting Authority provided that the tubes are subject to non-destructive testing by an appropriate method like ultrasonic or/and Eddy current testing”.

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
2001-04-10G.S.R. 219SubstitutedReplaced as part of the block substitution of regulations 36 to 56 (tube specifications).listed before the capture
2004-08-02G.S.R. 265AmendedRevises the definition of stress S, adding a basis for austenitic stainless steel.listed before the capture