Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)
Regulation 5 — Modification of Formulae
Text in the DPIIT web edition
Archived copy captured 03 Aug 2022 (Wayback Machine). The text matches the 2019 capture; amendments from 2020 onwards are probably not included. Units as printed.
| Reg. 5 Modification of Formulae |
| (i) | Under the Regulations for determining the working pressure to be allowed on various parts of boilers, the material to which the formulae apply shall in the absence of express provision to the contrary be steel complying with the requirements of Chapter II. |
| (ii) | Where no test certificate for plates and rivets are produced, the material may be treated as iron, if the Chief Inspector is satisfied that the material is of suitable boiler quality. If in such cases the Chief Inspector is clearly satisfied that the material is of good quality, a higher strength than that allowed for iron may be permitted but the strength of the plates shall not, save for special reasons, be assumed to be more than 26 tons per square inch. In such cases the values of tensile and shear strength shall not be more than 26 and 21 tons per square inch for steel, and 21 and 18 tons per square inch for iron. For iron across the grain the tensile strength may be 18 tons per square inch. |
| (iii) | For flat plates of copper, the working pressure as found from the formulae, reduced by 50 per cent shall be the working pressure permitted. |
Earlier text: the 2008 DIPP web edition
Modification of Formulae
(i)Under the Regulations for determining the working pressure to be allowed on various parts of boilers, the material to which the formulae apply shall in the absence of express provision to the contrary be steel complying with the requirements of Chapter II.
(ii)Where no test certificate for plates and rivets are produced, the material may be treated as iron, if the Chief Inspector is satisfied that the material is of suitable boiler quality. If in such cases the Chief Inspector is clearly satisfied that the material is of good quality, a higher strength than that allowed for iron may be permitted but the strength of the plates shall not, save for special reasons, be assumed to be more than 26 tons per square inch. In such cases the values of tensile and shear strength shall not be more than 26 and 21 tons per square inch for steel, and 21 and 18 tons per square inch for iron. For iron across the grain the tensile strength may be 18 tons per square inch.
(iii)For flat plates of copper, the working pressure as found from the formulae, reduced by 50 per cent shall be the working pressure permitted.
Amendments found
Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.
| Date | Notification | Part | Action | What changed (summary) | Web edition |
|---|---|---|---|---|---|
| 2020-09-11 | G.S.R. 551(E) | (ii) | Amended | Substitutes 'Inspecting Authority' for 'Chief Inspector'. | check the text |
Possible IBR 2026 successors (heading match, unverified): Reg. 26, Reg. 359