BETAIndependent engineering reference. Source-text verification is ongoing.Verification ongoing.Verification status →
IBRsourceIndian Boiler Regulations, made clear

Indian Boiler Regulations, 1950 (superseded 1 Oct 2026)

Regulation 40 — Flanging and drift expanding test

Unofficial DPIIT web edition · not verified1 amendment found

Text in the DPIIT web edition

Archived copy captured 03 Aug 2022 (Wayback Machine). This page was revised after the 2019 capture, so later amendments may be included. Units as printed.

Unofficial DPIIT web edition · archived 2022 · not checked against the Gazette
  [image] [image]


Message from
Chairman of Central Boilers Board
•
About Central Boilers
Board
•
History of Indian Boiler Regulations
•
Foreword
•
Contents Chapter
Wise
•
Contents Regulation
Wise
•
List of Amendments
•
Indian Boilers
Act 1923
•
Ibr Forms
•
Home
•
Search
•
Help
•
Contact Us

[image]

[image]
Reg. 40
MATERIALS OF CONSTRUCTION

COLD DRAWN SEAMLESS CAR BON STEEL BOILER, SUPERHEATER AND HEAT EXCHANGER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F).

Expanding or Flaring  test

A section of the tube approximately 100 mm in length shall stand being flared with a tool having a 60 degree included angle until the tube at the mouth of the flare has been expanded to the percentages given below, without cracking.

Ratio of inside diameter to outside diameter

Minimum expansion of inside diameter %

0.9

21

0.8

22

0.7

25

0.6

30

0,5

39

0.4

51

0.3

68

 

[image] [image]
[image] [image] [image]
Message from Chairman of Central Boilers Board • About Central Boiler Board • History of Indian Boiler Regulations • Foreword • Contents Chapter Wise • Contents Regulation Wise • List of Amendments
• Indian Boilers Act 1923 • Ibr Forms • Home • Search • Help • Contact Us
Earlier text: the 2008 DIPP web edition

MATERIALS OF CONSTRUCTION

COLD DRAWN SEAMLESS STEEL BOILER AND SUPERHEATER TUBES FOR DESIGN METAL TEMPERATURES NOT EXCEEDING 454°C (850°F).

Flanging and drift expanding test

(a)The tube shall withstand either the flanging test or the drift expanding test, at the option of the manufacturer.

(b)Flanging test:- A test piece cut from the end of a tube in a plane perpendicular to the axis of the tube shall show no crack or flaw after flanging to the specified outside diameter as given in the table below:

(c)Drift expanding test:- A test piece cut from the end of a tube in a plane perpendicular to the axis of the tube shall show no crack after expanding by a mandrel having an included angle of 30°, 45° or 60° at the option of the manufacturer to increase the outside diameter

Minimum increase of outside diameter of tubes in flanging and drift expanding test.

Type of test          Minimum specified  Outside diameter   Increase of outside
                      tensile strength(s)  (D) of the tube  diameter of the tube

                      Kgf/mm²            A=D<63.5mm         %
                                         B=63.5<D£150mm

Flanging test         S<42               A_____________     17
                                         B                  11
                      -------------------  -----------------------  ------------------14
                      S>42               A _____________    8
                                         B

Drift expanding test  -------------------  -------------------  -------------------

                                         A _____________    17
                                         B                  11

Amendments found

Machine-assisted list from the amending notifications (DPIIT copies; 1990–1998 from scanned Gazette issues on India Code); may be incomplete.

DateNotificationPartActionWhat changed (summary)Web edition
2001-04-10G.S.R. 219SubstitutedReplaced as part of the block substitution of regulations 36 to 56 (tube specifications).listed before the capture